14. Finger-tighten the top bolts to make sure the top and gasket are
seated properly. Then, tighten the bolts about halfway to full
torque value by tightening the opposite bolts. Finally, tighten
the bolts to ap proximately 30 inch-pounds (2.50 foot-pounds/
3.39 Nm) to fully secure the top to the canister. If the monito r
will not seal, loosen the bolts and check for a trapped wire or
debris on either the gasket or the lip. You can increase the
tor que value on the bolts incrementally to a ssist in sealing.
However , tighten t he bolts evenly to prevent distorting the
gasket and do not exceed 45-inch pounds (5.0843Nm).
15. Pla ce the monit or upright on the ground s urface beside the
manhole, and reco nnect the antenna cab le to the ANTENNA
port on the monitor.
16. Check the new battery voltage by activating the diagnostic
codes in the LED STATUS window on the monitor using the
red magnet. The internal voltage s hould now be well above 7.5
volts. Refer to Activating and Reading the Diagnostic Codes
on page 10-5 for instructions on initiating and interpreting the
codes.
17. Wrap rubber stretch tape around the entire antenna
cable/ANTENNA port connect ion, ext ending 1 t o 2 inc hes
onto the cable beyond the connection.
COAXIAL STRETCH TAPE
ANTENNA CABLE
TRITON+ MONITOR
ANTENNA PORT
Antenna cable connect ed t o ANTENNA port on monitor with st retch tape
properly applied
18. Reconnect the senso r cab le(s) to the appropriate port(s)
(Channel 1 and/or Channel 2) on the monito r.