User Manual
10-42 ADS TRITON+ Manual
Ultrasonic De pt h S ubs ystem
The following ta bles contain general troubl eshooting techniques for
prob le ms with the ultra so nic depth subsystem corresponding to the
Surface Combo Sensor and the Ultrasonic Depth Senso r .
Note: Contact your ADS representative for further
diagnosis prior to replacing a sensor.
Problem
Range from ultrasonic depth subsystem is slightly
inconsi stent with m anual l y measured range.
Possible
Causes
Physic al of fset may be incorrect.
Pipe height may be incorrect.
Elect roni c offset might be incorrect.
Possible
Solutions
Verify the physical off set, and adjus t i t if neces sary.
Verify the pi pe height.
Verify elec tronic off set and adjust i f necessary.