ADS® Enigma®/Enigma-Compact/ Enigma-hyQ User Manual November 2010 QR 775017 A2 ADS LLC 4940 Research Drive Huntsville, Alabama 35805 Telephone: (800) 430-3366 / Fax: (800) 430-6633 www.adsenv.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Copyright © 2010 ADS® LLC. All rights reserved. ADS® is a registered trademark of ADS LLC. Enigma® is a registered trademark of Primayer Limited. Microsoft®, Windows®, Windows Media®, and Windows Vista® are registered trademarks of Microsoft Corporation. Google Maps™ is a trademark of Google Inc. All other brand and product names are trademarks or registered trademarks of their respective holders.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Table of Contents Chapter 1 Introduction………………………………………………………………. 1 System Components.....................................................................................2 Technical Support ........................................................................................4 ADS Hassle-Free Warranty .........................................................................5 New Product Warranty .............................................................
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Network Button ....................................................................................65 Print Button ..........................................................................................72 Help Button ..........................................................................................73 Website Button.....................................................................................
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 1 Introduction The ADS® Enigma® is a compact, easy-to-deploy leak detection and location system designed for use with buried water pipes. Using the latest advances in digital acoustic technology, it combines noise logging (leak detection) and leak noise correlation (location) into a single, simple operation. Actual sound is recorded by a network of Enigma loggers, typically deployed on valves or hydrants overnight.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual System Components The Enigma system consists of the following components: 2 to 8 loggers Communications case (and USB lead) Enigma software (for installation on a PC) Enigma The Enigma-Compact system consists of the following components: 3 loggers Communications case (and USB lead) Enigma software (for installation on a PC) Enigma-Compact The Enigma-hyQ system consists of the following components: 2 3 loggers Communications
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual 3 hydrophones (with carrying case) Enigma software (for installation on a PC) Enigma-hyQ Note: The expected battery life of an Enigma logger is 5 years, based on performing 1 logging run (of 3 epochs) 5 times a week. Logging several times a day will reduce battery life.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Technical Support The ADS Support Center provides comprehensive technical support to assist customers in configuration and operation of the Enigma system. Contact customer support by email at adssupportcenter@idexcorp.com or by phone at (877) 237-9585.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual ADS Hassle-Free Warranty The following sections detail the hassle-free warranty and return policy for the ADS Enigma/Enigma-Compact. New Product Warranty ADS will repair or replace any Enigma/Enigma-Compact equipment (supplied by ADS) that is defective in materials and/or workmanship for up to two (2) years following the date of shipment from ADS.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Product Returns If the customer is not satisfied with the performance of the Enigma/EnigmaCompact, the customer may return the equipment within 30 days for a full refund, provided the condition of the equipment is in the same condition as sold, except for expected or normal wear and tear for the period of use.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 2 Software Installation To run the Enigma software, the user’s PC must have Microsoft® Windows® XP, Windows 2000, Windows Vista®, or Windows 7 and meet the following minimum software and hardware requirements: Microsoft Windows Media® Player 9 Pentium II 500 or equivalent CPU 512 Mb RAM 50Mb available hard disk space Available USB port Exceeding the minimum specifications will enhance operation and performance of the Enigma.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Installing the Software Note: Avoid running other applications during the software installation process. If necessary, close all other applications. 1. Insert the ADS installation CD into the CD-ROM drive on the PC. 2. The installation CD has an AutoPlay feature that should cause the CD to run automatically. If the CD does not run, perform the following procedure: Click Start > Run. Enter [CD-ROM drive designation]:\website_cd\index.html. Click OK.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 3 Hardware Overview The Enigma system consists of the following hardware: Logger set (each logger has a built-in accelerometer or connection for a hydrophone) Hydrophone set (required for hydrophone loggers only) Communications case This chapter provides a brief description of the system hardware and general instructions for using the communications case to program and readback the loggers.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Enigma Loggers Loggers (accelerometers) An Enigma logger is an approximately 4.3-inch (11-cm) long by 2.4-inch (6cm) diameter cylinder. One end of the unit contains a powerful magnet, which provides secure contact with ferrous materials during deployment. The other end has an optical window through which the unit communicates with the communications case. Each logger has an individual number for use when deploying the loggers.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Communications Case Enigma case with 8 loggers (left); Enigma-Compact case with 3 loggers (right) The communications case provides a protective environment in which to transport and store the loggers and the communications interface between the PC (using the host software) and the loggers. When connected to a PC through the USB port, the Enigma communications case allows for uploading of configuration information (recording settings, etc.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Programming/Readback of Loggers with the Communications Case Case Optical Windows (8) Program Button (green) Readback Button (red) LEDs (8) Logger Optical Window Inside top of transport case showing optical windows, LEDs, and buttons The communications case provides the following logger functions: Default programming Readback Program status check Readback status check The communications case can program a set of default logging paramete
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Note: Hydrophone loggers cannot be inserted into the case with hydrophones connected. Reconnect the hydrophone to the logger after programming and before the first epoch.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Checking Status - Programming Briefly press the green button. LED Indication On Logger programming was a success. Flashing Logger was detected, but failed programming Off Logger was not detected Readback Readback data from the loggers into the case in the following way: 1. Press the red button until the system begins beeping fast. 2. Close the case. Short beeps indicate that readback is in process. 3.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 4 Software Description This chapter contains reference and functional information for the various components of the Enigma software, including the main screen, main menu, submenus, and toolbar.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Main Screen Enigma software main screen The main screen contains the main menus, a toolbar, a folder section, and a viewing window.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Main Menu The main menu contains five menus: File, View, Communications, Tools, and Help. File Menu File menu The File menu contains the following options: New Open Close Save Save As Print Preview Print Exit New The New menu contains the Enigma Folder option: Enigma Folder Selecting this option displays the New Enigma Folder wizard.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual New Enigma Folder wizard (Select Folder Type window) From this location, you can select either an Enigma Folder that contains configuration and network files or an Empty Folder that contains no information files. Selecting the folder type and the Next button displays the Select Folder Location window. Select Folder Location window From this window, you can navigate to the location to create the new folder.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual folder is saved to the logger during the programming sequence so that data read from the loggers can be saved to this predefined location. After making entries down to the second level, you can click on the Auto Fill button to prefill subsequent entries. Where similar entries already exist, the auto fill option adds a bracketed number. Open The Open menu contains the Open Enigma Folder option. Open Enigma Folder Selecting this option opens an Enigma folder.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Exit This option closes and exits the Enigma software. View Menu View menu The View menu contains the following options: Directory Settings Network Setting Directory Settings Selecting this option displays the Enigma Options wizard for defining the default database directory and data readback directories. The default prefix and postfix information also can be set through this option. 1.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Directory labels window 5. Click on the Finish button Network Settings Selecting this option opens the Network Settings Wizard for setting the network configuration file and a map file, if required. Both settings will be associated with the current sound file. However, before opening the Network Settings options, you must open an Enigma Database file.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Network Settings Wizard Network Configuration File Select the network configuration file by navigating through the directory in the top part of the window. The selected file displays in the Network Configuration File field. Map File Set the network map file from this section. This file is a BMP image file typically representing a map or an aerial photo that will serve as the background to the map view.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Communications Menu Communications menu The Communications menu contains the following options: Logger Programming Case Programming Logger Readback Case Readback Logger Programming Selecting this option launches the Program Wizard for programming the loggers. Refer to the Program Button section on page 31 for more detailed information.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Case Configuration Wizard (Program Wizard window) Refer to the Program Button section on page 31 for more detailed information. Click on the Program button to program the default settings into the case. Logger Readback Selecting this option initiates the readback of data from the loggers in the case through the USB port on the PC. For more detailed information, refer to the Readback Button section on page 37.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Tools Menu Tools menu The Tools menu includes three options: Pipe Data Entry Velocity Measurement Maximum Time Delay Pipe Data Entry To accomplish meaningful leak correlations, you must enter pipe data for each section of pipe.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual entered values. However, for greater accuracy, calculate the actual velocity using data collected from 3 loggers. The Enigma-Compact is optimized with 3 loggers for calculating velocity to improve the accuracy of leak detection. For more information, refer to Velocity Measurement on page 75. Maximum Time Delay Selecting Maximum Time Delay provides the option settings for controlling the analysis and displays the currently selected maximum time delay.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Toolbar Buttons The toolbar buttons display at the top of the program window. Folders Button Clicking on the folders button displays the folder window. This window shows a standard windows folder tree for navigating through the structure to view and select items. Hide the folder window by clicking on the x at the top right corner of the folder window.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Search Criteria window Search Criteria Specify the search item or part of the item for which you are searching in the All or part of the folder name field. Select All Folders or an Enigma Folder from the Type of Folder drop-down list. Browse Folders Clicking on the Browse Folders button opens the browse view for designating the directory location in which to conduct the search.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Search Criteria browser window When Modified This feature allows you to refine the search parameters by choosing the time period for which to conduct the search. Select one of the following options: Within the last week Within the last month Within the last year Specify dates Choosing the Specify dates option requires that you select Modified date, Created date, or Accessed date and then specify the exact date range for the search.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Clicking on the from and to drop-down arrows opens a date selection dialog. Date selection dialog The current date is shown in a red box; the selected date is shown in a blue square. Click on the required date to set the date parameter. Click on the arrows at the top of the date selection dialog to scroll through the months. Clicking on the Today line at the bottom of the dialog selects the current date.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Program Button Clicking on the program button displays the Enigma Program Wizard window (once a connection is established) through which you can program the loggers directly from the PC. This method involves using the case solely as an interface. Enigma Program Wizard Epoch Times This part of the wizard allows you to select the required epochs. Epoch 1 is required; Epochs 2 and 3 are optional.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Timed Logging To set the time for Epoch 1, select the hour portion of the Time field and then designate the desired hour using the corresponding up and down arrows. Repeat this process for the minute portion of the Time field. To set the times for epochs 2 and 3, select the appropriate cycle (from 2 to 60 minutes) from the corresponding Interval drop-down list. By default, the epoch times are 02:00, 03:00, and 04:00 at 60-second intervals.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Define Data Store Select Data Store window Use the Select Data Store screen to designate the location to which to save the logged data once it is retrieved. The file location information may be entered manually or pre-filled by clicking on the navigation tree. (This feature is useful when revisiting a previously surveyed site.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Program This initiates programming of either the loggers or the communications case. Programming involves verifying the synchronization of the loggers’ clocks. Programming loggers A confirmation dialog box displays the number of loggers found. Click OK to continue programming. If the number of loggers displayed is not correct, clean the optical windows on both the case and the loggers and then restart the programming sequence.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Program completed The programming results display on the main screen.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Programming confirmation and results This screen confirms the loggers that were programmed and provides details of the epochs that were set up. Notice that the example shows a full set of 8 loggers. The results should reflect the number of loggers used. Cancel Clicking on this button closes the program wizard and terminates programming. Help Clicking on this button opens the help file.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Readback Button Clicking on the readback button initiates data collection from the loggers. Readback includes the following stages: Establishing communication with the loggers Selecting the data storage location (manual selection) Reading back data from the loggers Enigma Readback – progress of establishing communications A confirmation dialog box displays showing the number of loggers to be read back. Click OK to continue readback.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Enigma Readback Wizard (Select Data Store window) From this location, you can select the location to which to save the readback data. The file location information may be entered manually or pre-filled by navigating to the appropriate location on the tree. (This is useful when revisiting a site surveyed previously.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Results – Main Display The number of results depends on the number of loggers used. This example involves 8 loggers. If only 3 loggers had been used, the results of only 3 results would be available. Data analysis may require a significant amount of time based on the amount of data and the speed of the PC. The progress displays in the data window. As the analysis occurs, the matching results display as thumbnails.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Normalize Checkbox Selecting the Normalize Charts checkbox enables the normalize function that equalizes the height of each correlation thumbnail. Correlation thumbnail Correlation thumbnail normalized Sort Drop-down List The option selected from this list determines the method by which the software will sort the thumbnail results. Selecting Peak sorts the thumbnail results based on the quality of the correlation peak (i.e.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Leak analysis with the thumbnail results sorted based on the peaks Confidence Checkbox Selecting this checkbox colors the background of the correlation thumbnails based on the degree of confidence that the correlation peak represents a leak. The software indicates confidence based on the presence of the peak in all epochs, the consistency in the approximate shape of the peaks, and the peaks sharing the same position on all epochs.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Sort and confidence display Instances may occur where sort and confidence processing indicates a lack of consistency in the ordering of thumbnails with red and yellow backgrounds. When this occurs, examine the three epochs of the correlations to identify a potential reason that the colors may be out of order.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Disable Correlations may be disabled and excluded from the analysis. To disable a correlation, right-click on the correlation and then select the Disable option. The software moves disabled correlations to the end of the main display and excludes them from the calculations. To turn off the disable function for a particular correlation, right-click on the correlation and deselect Disable.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Analysis Toolbar The top line of the display identifies the two loggers that were analyzed for the results and includes several options. The two loggers that were analyzed to generate the correlation display in blue and red. To change the current loggers, select the desired loggers from the corresponding drop-down menus. Analysis toolbar The top part of the screen displays the Correlation Analysis and peaks that have been identified.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Noise Suppression This option applies noise suppression to a correlation. To use this option, select the Noise Suppression checkbox and then click and drag the cursor over the time delay range chosen for suppression.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Post noise suppression To turn off noise suppression, deselect the Noise Suppression checkbox. Epochs The three checkboxes associated with Epochs determine whether individual epochs display or are hidden from view. Selecting the checkbox for an epoch displays the corresponding epoch. Hidden epochs are not used in correlation calculations.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Zoomed section of display showing the zoomed section of pipe dB / Frequency display When the display is set to show coherence, it is shown on the right side of the graph in green.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Find Peak Clicking on this button moves the cursor on the correlation display to the peak value, as determined by the software. You also can move the cursor by clicking on the cursor marker and then dragging it to the left or right using the mouse. The time delay figure for the cursor position displays above the cursor marker. Move the cursor in shorter, more precise segments using the left and right cursor keys.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Add a section of pipe in the following way: Note: Pipes must be added in the correct order, from the left logger to the right logger. 1. Click on the Insert button. The New Pipe Span Details window displays. New Pipe Span Details window 2. Select the type of material from which the pipe is made from the Material drop-down list. The following figure shows the available materials. Available pipe types (materials) 3. Enter the Length of the pipe. 4.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual New Pipe Span Details window populated 5. If a velocity value is required, select the User Defined Velocity checkbox and enter the appropriate Velocity. 6. Click on the Insert button to add the pipe to the network. New pipe section added on Pipe Details window 7. If more than one type of pipe exists between the two loggers, add the next section of pipe by repeating steps 2 through 6. Repeat these steps for each additional section as necessary.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual 8. Click on the OK button to initiate the process of adding the pipes to the network. Delete a section of pipe in the following way: 1. Click on the pipe section to delete in the Pipe Details window. 2. Click on the Delete button. 3. Click on the OK button to confirm the changes. Modify a section of pipe in the following way: 1. Click on the pipe section to modify in the Pipe Details window. 2. Click on the Modify button. 3.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Filters tab Analysis Options and Filter Settings (Filters tab) Note: The default values for hydrophones are different than those shown in the image. Therefore, when using the hydrophones, ADS does not recommend using Auto Filter. The Analysis Options and Filter Settings dialog allows you to select various filters and options to manage the leak detection process. The filters are band pass filters. You can select up to three.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Filters 1 to 3 This feature allows you to select up to 3 filter bands manually. This can be done either by clicking the filter box and manually entering the filter frequency required or by dragging and dropping on the frequency spectrum display. Restore Default Filters Selecting this button restores the default settings.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Advanced Options on Filters tab Advanced Options This section includes several advanced filtering options. Equalize Auto Filter Selecting this option applies the Spectral Equalizer while the Auto filter is processing data (rather than afterwards). Occasionally, this filter can improve the correlation result. Using this option may increase the operational time. Refine Auto Filter Selecting this employs the refined auto filter.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Center Correlation Suppression Width Center correlation peaks occur due to unwanted noise that is common to both loggers. Designate the number of milliseconds of correlation data to remove from the center of the correlation. Display Coherence Selecting this option adds a third green trace to the frequency display. The coherence shows the similarity between the two logger recordings at each frequency.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Low and High fields reflect selected (highlighted) filter Adding a Filter Enter the high and low settings for the new filter in the High and Low fields below the table, and then click on the Add button. The new filter settings display on the table. Deleting a Filter Select the filter on the table for removal, and then click on the Delete button. The selected filter settings disappear from view.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Narrow Band Filtering tab When an epoch is open, click on the Run button to apply the narrow band filters. Throughout processing, the filtering results will display on the right hand side and the section of the epoch currently under analysis will be highlighted on the left. Once processing is complete, the filter settings display in the Filter tab and are available for modification (if required).
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Auto Velocity at Out of Bracket If, during the analysis, a peak displays close to a logger position, but should display at the end, use the Out-of-Bracket function to compensate for the inaccurate velocity of sound in the pipe. Note: Use this function only when a known out-of-bracket condition exists. To obtain an accurate result using this function, the value entered for the distance between the sensors must be correct.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Once re-correlation is complete, the peak moves to the end of the pipe and the calculation changes the default value to a calculated value.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Leaks (Leak Markers) Selecting this button allows you to mark leaks or points of interest found on the pipe model. Leak markers will display automatically in Network Mode. However, please note that leak markers that are out of bracket will display on the analysis screen, but not in Network Mode.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Epochs Button Selecting this button displays the Epoch screen that displays 2- and 3dimensional views of the correlation functions produced in each epoch. Viewing the epochs is beneficial to determining whether a correlation peak represents a leak (present in all epochs) or non-leak noise, possibly from customer water usage (not present in all epochs).
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Time Delay This field displays the time delay at the cursor location. The marker above the Epochs on the left side of the display and the triangle under the lower edge of the 3-dimensional display indicate the location of the cursor. Move the cursor by dragging the cursor located above the epoch on the left side of the screen with the mouse or by using the left and right cursor keys (for limited, minimal movement).
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Sound Button Clicking on this button opens the sound window. The sound window shows the sound displays of the logger recordings. Sound Display The display includes the following features: Control buttons Volume control Info displays Logger number Critical Noise Value Sound graph Click on a sound graph to select which sound to play.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Control Buttons The control buttons manage the playback of sound through the PC speaker or headphones (when applicable). Sound control buttons Play/Pause Selecting this button plays the sound through the PC sound system (i.e., speakers or headphones). Stop Selecting this button terminates playback of the current sound. Backward Selecting this button moves the sound cursor back 10 seconds and continues playback from the new position.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Info Displays Information displays Logger Number This represents the number of the logger, which also displays on the top of the logger. Critical Noise Value This represents the critical nose value. The key to the values and colors is available at the top of the window. Sound Graph This is a graphical representation of the sound recorded by the logger. Network Button Clicking on the Network button displays the Network screen.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual the network to add pipe data, enter all pipe lengths to ensure that accurate pipe details will be used in the Analysis screen. Network screen Loggers with data have a thick blue border; loggers without data have a thin grey border. Network Window – Tools The menu on the left side of the screen includes the following tools. Selecting a specific tool displays the corresponding content on the right.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Text Use this tool to add text entries onto the network diagram. Noise Use this tool to place a manual noise point on the network. For example, use it to mark the location of a known source of noise in an area by placing the noise source onto the pipe location and adding a comment defining the source. Pipe Join Use this tool to create a pipe join. Properties Select this checkbox to open the properties display on the right side of the window.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Background Use this option to implement a user bitmap or JPG, such as a map, as the background display. Show Notes Select this checkbox to display user notes with an object on the network screen. Enter the notes for display by selecting the object on the screen and entering the text in the Notes field on the Properties tab.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Correlation Tab Clicking on the Correlation tab displays the correlations. If the correlations do not display, click on the Refresh button to refresh the display. Doubleclicking a correlation displays the full analysis on the left side of the screen. Displaying correlations at right Map Tab Clicking on this tab using a computer connected to the Internet launches Google Maps™ for the map background. Map tab Position the map on the screen as required.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Search Use the features in this section to locate the correct map upon which to overlay the network. Address/Postcode Enter the address for the Google search. Country Enter the country in which to search. Map Type Select the type of map required for the overlay from the drop-down menu. Search Click on this button to initiate the search for the map based on the selections and information provided.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual noise sources also will display on the map. If an element exists off the screen, click on the Locate button corresponding to the element to orient the display so that the element serves as the central item on the display. Any leak markers identified through correlation analysis will also display on the map. The estimated locations for these are determined based on the pipe details entered.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Print Button Clicking on the Print button displays the print window.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual The print window shows the currently selected data with some buttons at the top. Display/hide the dB values (Critical Noise Values) on the report by selecting/deselecting the Critical Noise Values checkbox.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual 74
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 5 Velocity Measurement Using three loggers to calculate the velocity of sound in the network ensures more accurate leak position detection. However, before measuring velocity, make sure the correct pipe information has been entered. 1. Select Tools > Velocity Measurement to launch the Velocity Measurement Wizard. Velocity Measurement Wizard (Select Loggers window) 2.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Confirm pipe lengths window 4. Verify that the distances are correct. If no distances have been entered, you will receive a warning and be required to exit the wizard. (Enter pipe details between the appropriate loggers using the pipe data entry screen.) 5. Click Next to continue.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Mark Noise Source window 6. Move the cursors to the peak values by clicking on the Go To Peak buttons or by clicking and dragging the individual cursors. 7. Click Next.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Measured Velocity Results window If the selected peak values are valid, the calculated velocity and a revised (improved) leak position will display. Use the velocity value in the Analysis screen by clicking on the question displayed and entering the logger numbers.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 6 Battery Replacement The communications case is powered by a disposable battery pack with a typical battery life of approximately 5 years. The PC software provides a low battery voltage indicator available during communication with the case or loggers for checking the status. When necessary, users may replace the battery pack in the Enigma communications case. New battery packs are available through ADS.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual 80
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual CHAPTER 7 Principles of Leak Noise Correlation Note: ADS strongly recommends that all users read this section, even those with prior experience in correlation techniques. Leak Noise The loss of water through a leak in a pipe creates a source of noise. This noise, which travels from the leak in both directions (upstream and downstream), is used to determine the location (or source) of the leak.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual between the arrival of the noise at A and at B. Assume the velocity of sound is V, and the distance between the loggers is D. If the distance from X to B = V * t, then D = (2 * L) + (V * t).
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Noise Sources Close to Loggers Loggers located directly over or very close to a leak may not be able to accurately locate the source of the leak noise. When this occurs, move the affected logger further away from the source of noise. Problems with Trunk Mains and Plastic Pipes It may be difficult to obtain satisfactory correlation when examining trunk mains or long lengths of plastic pipe.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual 84
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Appendices The following appendices provide information about the maximum allowable distances between loggers in pipes, sharing Enigma data, and transporting Enigma systems by air.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Appendix A: Maximum Deployment Distances The maximum permissible distance between deployed loggers varies according to the pipe material. Refer to the following table to determine the maximum distances. Do not exceed these distances.
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Appendix B: Sharing Enigma Data Enigma deployment and correlation analysis data may be shared among other user PCs, if required. Share the data by copying the data folders from one PC to another using a typical Windows file manager and any suitable transfer media (e.g., memory sticks).
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Appendix C: Important Notice – Air Transporting the Enigma IATA Hazardous Goods Regulation This product is powered by a battery containing either lithium C-cells or Dcells. Air-freighting of products containing these lithium cells is governed by IATA (International Air Transport Association) regulation UN/ID number 3091 entitled ‘Lithium batteries contained in equipment.
ADS Enigma/Enigma-Compact User Manual Index A ADS Website, 73 Advanced Filter Options, 53, 54 Center Correlation Suppression, 54 Display Blue Spectrum, 55 Display Coherence, 55 Equalize Auto Filter, 54 Refine Auto Filter, 54 Air Transportation Notice, 88 Analysis, 43 Correlation Function Tools, 47 Toolbar, 44 Analysis Button, 43 Analysis Toolbar, 44 Epochs, 46 Noise Suppression, 45 Auto Filter, 52 Auto Velocity at Out of Bracket, 58 B Battery Power, 10 Battery Replacement, 79 Buttons, 27 ADS Website, 73
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual Epochs Button, 61 Exit, 20 F Features, 1 File Menu, 17 Close, 19 Exit, 20 New, 17 Open, 19 Print, 19 Print Preview, 19 Save, 19 Save As, 19 Filters, 51 Advanced Options, 53, 54 Narrow Band Filtering, 55 Peak Enhancer, 53 Spectral Equalizer, 53 Find Peak, 48 Folders Button, 27 H Hardware Overview, 9 Hardware Requirements (Minimum), 7 Help Button, 73 Help Menu, 26 Hydrophone, 1, 10, 11, 13 I Info Displays, 65 Installing Software, 8 L Leak Beyond Loggers, 82
ADS Enigma/Enigma-Compact User Manual P Peak Enhancer, 53 Pipe Data Entry, 25 Manual, 25 Network Schematic, 25 Pipework, 48 Positioning Errors, 82 Leak Beyond Loggers, 82 Leak on Connecting Pipe, 82 Noise Sources Close to Loggers, 83 Power, 10 Principles of Leak Noise Correlation, 81 Print, 19 Print Button, 72 Print Preview, 19 Print Screen Buttons, 73 Problems with Trunk Mains and Plastic Pipes, 83 Program Button, 31 Programming, 31 Communications Case, 12, 13, 23, 34 Controls, 13 Epoch Times, 31 Loggers,
ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual V Velocity Measurement, 25, 75 Velocity of Sound, 75 View Menu, 20 Directory Settings, 20 Network Settings, 21 Volume Control, 64 92 W Warranty, 5 Website Button, 73 Z Zoom, 46, 67 Zoom Out, 48