User guide

ADS Enigma/Enigma-Compact/Enigma-hyQ User Manual
14
Checking Status - Programming
Briefly press the green button.
LED Indication
On Logger programming was a success.
Flashing Logger was detected, but failed
programming
Off Logger was not detected
Readback
Readback data from the loggers into the case in the following way:
1. Press the red button until the system begins beeping fast.
2. Close the case. Short beeps indicate that readback is in process.
3. After hearing a long beep, indicating the readback process is complete,
open the case.
4. Check for a solid LED for each logger to verify readback success. A
flashing LED indicates a failure to readback. Logger status displays
for only 8 seconds. To re-display the status information, follow the
instructions in the following section, Checking Status - Readback.
If readback fails, repeat the readback process.
Once the readback process is successful and complete, use the PC to retrieve
the information stored in the case. Reprogram and redeploy the loggers as
required.
Checking Status - Readback
Briefly press the red button.
LED Indication
On Logger readback was a success.
Flashing Logger was detected, but readback
failed.
Off Logger was not detected.