LOW_LEVEL
T
(detected by monitor)
Low Depth This event indicates that the flow depth
has fallen below the Low Depth threshold
(configured in Profile). When this occurs,
IntelliServe broadcasts a Low Depth
event.
NO_CURVE
T
(detected by monitor)
No Curve This indicates that no depth-to-velocity
relationship exists.
NON_ADS_FLOW_
QUANTITY
HT
Quantity of Flow
(non-ADS flow
monitor)
This represents the flow quantity measured
using a non-ADS flow monitor.
PEAKVEL_1
HST
Peak Velocity1 The represents the peak velocity data from
the Peak Combo Sensor.
PEAKVEL_3
HST
Peak Velocity3
This represents the peak velocity data from
the Surface Combo Sensor.
PDEPTH
HST
Pressure Depth This represents depth data from the
pressure depth sensor.
PDEPTH_1
HST
Pressure Depth1 This represents pressure depth data from
the Peak Combo Sensor.
PDEPTH_2
HST
Pressure Depth2 This represents pressure depth data from
either the pressure depth sensor or the
Profiler Combo Sensor.
PDEPTH_3
HST
Pressure Depth3 This represents pressure depth data from
the Surface Combo Sensor.
PD_USED
T
(detected by monitor)
Pressure Depth
Used
This event (Pressure Depth Readings
Used) indicates that Pressure Depth
represents Unidepth in the monitor.
PIPE_CAPACITY
HT
Pipe Capacity This represents the pipe capacity (defined
by the System Administrator).
PIPE_HEIGHT
HT
Pipe Height This represents the height of the pipe at
which the sensors are installed (defined by
the System Administrator).