Manual

B-10 IntelliServe
User’s Guide
CONFIDENTIAL Covered by ADS Terms of Use and Confidentiality Agreement in Contract
© 2010 ADS LLC. All Rights Reserved.
SDEPTH2
HST
Smarth Depth2 This represents a single ultrasonic reading
derived by the Smart algorithm in the
monitor using all 12 ultrasonic depth
sensor readings from a second sensor.
SILT
HT
Silt This represents the depth of the layer of
dirt and debris that has collected at the
bottom of a pipe over time. This value is
entered manually.
SURFACEVEL_3
HST
Surface
Velocity3
This represents raw velocity measurements
from the Surface Combo Sensor.
TEMP
HT
Temperature
This represents the temperature read using
the temperature sensor in an active
ultrasonic temperature sensor. It is
recorded by the monitor once a day at
midnight.
TEMP2
HT
Temperature2 This represents the temperature read using
the temperature sensor in a second active
ultrasonic temperature sensor. It is
recorded by the monitor once a day at
midnight.
U2 - U15
HST
Ultrasonic
Sensor Pairs
These represent raw depth data from the
ultrasonic depth sensor pairs.
UNIDEPTH
HST
Unidepth
This represents the MLI depth entity
generated by the monitor using ultrasonic
depth sensor data and/or pressure sensor
depth data.
UpDEPTH_1
HST
Ultrasonic
Depth1
This represents ultrasonic depth from the
Peak Combo Sensor (uplooking).
UpDEPTH_2
HST
Ultrasonic
Depth2
This represents ultrasonic depth from the
Profiler Combo Sensor (uplooking).
UTEMP
HT
Ultrasonic
Temperature
This represents the temperature read using
the temperature sensor in an active
ultrasonic sensor. It is recorded by the
monitor once a day at midnight.
UTEMP2
HT
Ultrasonic
Temperature2
This represents the temperature read using
the temperature sensor in a second active
ultrasonic sensor. It is recorded by the
monitor once a day at midnight.