ADS® PrimeLog® User Manual August 2009 QR 775015 A0 ADS LLC 4940 Research Drive Huntsville, Alabama 35805 Telephone: 1-800-430-3366 / Fax: 1-800-430-6633 www.adsenv.
ADS PrimeLog User Manual Copyright © 2009 ADS® LLC. All rights reserved. ADS® is a registered trademark of ADS LLC. PrimeWorks® and PrimeLog® are registered trademarks of Primayer Limited. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. All other brand and product names are trademarks or registered trademarks of their respective holders. Notice of Proprietary Information The information contained herein represents the latest information available at the time of publication.
ADS PrimeLog User Manual Table of Contents Chapter 1 Introduction................................................................................................ 1 System Features .......................................................................................... 2 Logging Range Features........................................................................ 2 Main Features........................................................................................ 2 Logging Features....................
ADS PrimeLog User Manual Chapter 6 Appendices................................................................................................ 22 Appendix 1: Meter Scaling Tables........................................................... 23 Elster/Kent Helix & Domestic Meters ................................................ 23 Schlumberger/Actaris/Stream Domestic & Helix Meters................... 23 Sensus (Socam/Meinecke) ..................................................................
ADS PrimeLog User Manual CHAPTER 1 Introduction PrimeLog® is a family of advanced submersible data loggers, designed specifically for applications in the water industry. Common applications include the following: District, residential, and leakage flow monitoring Network analysis Pressure monitoring PRV (pressure reducing valve) monitoring Open channel flow monitoring Reservoir and borehole depth measurement The different loggers offer one, two, or four data input channels.
ADS PrimeLog User Manual System Features Logging Range Features Standard (non-modem) Logger 1F 1A 1P 2i 2 4 4i Total number of channels 1 1 1 2 2 4 4 Total number of bi-directional flow channels 1 1 1 2 2 1 2 Number of analog channels (for transducer, voltage, or current input) 1 Number of internal pressure channels Pressure / analog channel accuracy (%) ±0.1 1 1 ±0.5 or ±0.1 ±0.1 2 ±0.1 ±0.1 ±0.
ADS PrimeLog User Manual Variety of measurement modes Cyclical Designated time period Memory limited (stops logging when memory is full) Multiple data collection options All data Since last collection Defined date range Substantial data storage Standard: 128K RAM (approximately 1 year at 15-minute interval) Optional: 256K, 512K, and 1M Flow and Pressure Logging Logs data from all flow meters (e.g.
ADS PrimeLog User Manual Logger Types The following table includes the types of loggers available: 1F Flow 1P Pressure 2i Flow + Pressure 2 2-channel 4 4-channel Digital input Analog input Internal pressure transducer 4
ADS PrimeLog User Manual ADS No-Hassle Warranty and Return Policy The following sections detail the hassle-free warranty and return policy for the ADS PrimeLog. New Product Warranty ADS will repair or replace any PrimeLog equipment (supplied by ADS) that is defective in materials and/or workmanship for up to two (2) years following the date of shipment from ADS. To make a warranty claim, the customer should simply call ADS at (256) 430-3366 or contact the ADS Support Center toll-free at (877) 237-9585.
ADS PrimeLog User Manual Product Returns If the customer is not satisfied with the performance of the PrimeLog, the customer may return the equipment within 30 days for a full refund, provided the condition of the equipment is in the same condition as sold, except for expected or normal wear and tear for the period of use.
ADS PrimeLog User Manual CHAPTER 2 System Overview Note: This manual provides information on most standard features and applications; however, ADS cannot anticipate all possible configurations or applications involving the PrimeLog. Therefore, some information may not be included in this manual. Please contact the ADS Support Center at supportcenter@idexcorp.com or (877) 2379585 for assistance, when necessary.
ADS PrimeLog User Manual PrimeLog PrimeLog submersible data loggers are available with one to four input channels and various power options. An internal pressure transducer is available with all models. The tables in the Introduction outline the range of loggers and features available. This section offers additional information and details for the various logger types. All loggers are equipped with military-grade connectors and are sealed according to IP68 specifications.
ADS PrimeLog User Manual Auxiliary Battery Unit An auxiliary battery unit containing 6 C-size alkaline cells is available to supply additional power to digital sensors with heavy current demands. When selecting this kind of sensor for a logger (through the Logger Setup and the Digital tab options – refer to the PrimeLog Menu section of the ADS PrimeWorks User Manual), the user receives notification through a warning message of the requirement to use the battery unit.
ADS PrimeLog User Manual CHAPTER 3 Hardware Connections This chapter provides details concerning sealing, polarization, and inputs.
ADS PrimeLog User Manual Sealing The PrimeLog connectors are waterproof only when used with a mating connector, or when the captive sealing cap is connected. For continued full environmental protection, the sealing caps must be secured when the connector is not in use. Sensors supplied by ADS come with sealed mating connectors. Attach connectors using a bayonet (twist-and-click) action of the rotating shell. Connectors will not seal correctly if foreign matter is present between the mating surfaces.
ADS PrimeLog User Manual Polarization All PrimeLog connectors are polarized, making it impossible to connect a device to the wrong input.
ADS PrimeLog User Manual PrimeLog Input Connections The connectors on PrimeLog include logos for identification. The following sections describe the connections and show the corresponding logos. WARNING: Due to the operational requirements of depth transducers, never immerse the connector in or expose it to water. The vent tube from the transducer sensor terminates at the connector and must be open to the atmosphere to sense pressure in vented gauge mode.
ADS PrimeLog User Manual Analog Inputs The PrimeLog has two types of analog inputs: general purpose and dedicated integral pressure transducer. General analog inputs may be voltage or current. Voltage input range is nominally 0 - 21V DC. Voltages outside this range require a special cable; standard voltage ranges available are 0 - 5V and 0 10V. Current input requires a special cable suitable for 0 - 10mA, 0 - 20mA, and 4 20mA ranges.
ADS PrimeLog User Manual CHAPTER 4 Installation and Use Installing the logger primarily involves connecting the cables to the inputs. Sensors supplied by ADS come with the appropriate connector.
ADS PrimeLog User Manual Logger Setup Set up the logger by running the support software. Refer to the ADS PrimeWorks User Manual for more information.
ADS PrimeLog User Manual Logger Use Data may be downloaded through a local connection at any time without interrupting the recording of data. No special procedure is required when the logger is in use.
ADS PrimeLog User Manual CHAPTER 5 Interfacing This chapter provides information about interfacing the PrimeLog with various probes and sensors.
ADS PrimeLog User Manual Quadrina Insertion Meters Quadrina insertion meters are probes that are inserted, usually on a temporary basis, into mains supply pipes and measure velocity. The Quadrina Range ADS supplies these probes in two sizes, standard (Probeflo) and miniature (Miniprobe), and both are equipped for unidirectional or bi-directional flow. While two options of the insertion tube are available, eight hardware variations exist.
ADS PrimeLog User Manual velocities. A mean factor also is calculated from these values. While this factor offers convenience, it also introduces some level of error. Logger Configuration After selecting the Quadrina Insertion Probe option from the PrimeWorks flow meter menu, the following information must be provided: Probeflo (default) or Miniprobe Unidirectional (default) or bi-directional Standard (0.5-inch) or oversize (0.
ADS PrimeLog User Manual Other Flow Meters Interfacing the PrimeLog instruments with other flow meter sensors requires an adequate knowledge of the power requirements of these sensors. The following table specifies the power interface: Powering Standard Sensors Type 1 - Contact Closure Sensor Kent PSM/LRP/MSM/PU10 Power Source Data logger Kent Helix 4000 Reed Switch Meinecke/Socam K01/K505R/K510/RO2.
ADS PrimeLog User Manual CHAPTER 6 Appendices The following appendices provide meter scaling tables, product specifications, and important information about air-freighting the PrimeLog.
ADS PrimeLog User Manual Appendix 1: Meter Scaling Tables Elster/Kent Helix & Domestic Meters Meter PU10/LRP (mm) 40-80 100-300 40-80 100 150 40-50 80-100 Helix 2000 Helix 3000 Master 2000 80-125 150-300 Helix 4000 PSM-PS15-PS20 (V100) PSM-PS25-PS30 (V100) PSM-PS40 (V100) PSM-LT (V210) MSM-T (V100) KVM-T (V200) MSM-RS 15/20 25-30 40 15 & 20 PU100/HRP FCAL 10 100 10 10 100 1 10 PVG100 10/1000 100/10000 PSM 0.5 5 5 0.5 1 10 1 1 10 0.
ADS PrimeLog User Manual Sensus (Socam/Meinecke) Meter K510 (mm) 510/510PR 501L 501LM 501JM 510/510PR 501JM 15-20 25-30 Cosmosil 50-125 150-250 300-800 Cosmos 50-125 40-125 WP/WS-Dynamic 150-300 K505R FCAL 1 10 100 1000 10 100 R01.1 100/1000 1000/10000 10000/100000 RD 01 100 100/1000 10/1000 1000/10000 100/10000 0.5 5 OPTO 06 1 10 100 OD 07 1 10 Supplementary Notes for Meter Scaling Tables: FCAL = NO.
ADS PrimeLog User Manual Appendix 2: Specifications Inputs 1, 2, and 4 channels Dedicated Models Single channel flow Single channel pressure 2-channel (1 flow/1 pressure) 4-channel (2 flow/2 pressure) General Purpose 2-channel (1 analog/1 digital) 4-channel (2 analog/2 digital) Digital Channels Frequency Bi-directional Conversion Compatibility 0 - 500 Hz max YES - 2 pins provided 10-point table Voltage-free contact/open drain FET Socam / Meinecke RO1.
ADS PrimeLog User Manual Outputs Alarm Local Comms Data Collection One per channel 19,200 baud All data / data since last reading / designated date range Logging Types Modes Capacity Interval Features Count Cyclical / designated time period / stop when memory is full 128 Kbytes (approximately 1 year at 15 minutes per channel) 1 second to 24 hours Independent logging per channel Power Lithium Battery Design life 5 years (see note on page 2) Factory or agent replaceable (Calculation is based on a 15-minu
ADS PrimeLog User Manual Appendix 3: Important Notice - Air-Freighting This Product IATA Hazardous Goods Regulation This product is powered by a battery containing lithium C-cells or lithium Dcells. Air-freighting of products containing these lithium cells is governed by IATA (International Air Transport Association) regulation UN/ID number 3091 entitled ‘Lithium batteries contained in equipment.’ This regulation clearly states that this equipment is classified as Hazardous Goods, Class 9.
ADS PrimeLog User Manual CHAPTER 7 Index Air-Freighting, ii, 27 Analog Inputs, 14 Auxiliary Battery Life, 21 Auxiliary Battery Unit, 9 Auxiliary Battery/Communications Adaptor, 9 Battery, 9 Battery Unit Auxiliary, 9 Calibration, 19 Communication Link, 14 Connections Input, 13 Digital Inputs, 13 Flow and Pressure Logging, 3 Flow Meters, 21 Interfacing, 18 Internal Pressure Transducer, 13 Kent Meters, 24 Lithium, 27 Logger Configuration, 20 Logger Setup, 16 Logging Features, 2 Master Meters, 23 Meter Scali