Readback
The Readback function enables the user to download data from a logger into the
PrimeWorks database.
Selecting the Readback option from the PrimeLog menu displays the
PrimeLog Readback dialog. Empty fields indicate that no data is available
because readback has not yet occurred.
PrimeLog Readback dialog
The radio buttons on the dialog allow the user to designate whether to readback
all or only a portion of the data from the logger:
Read All Data Selecting this options reads back all data contained in
the logger. If the logger configuration has just been read, the range of
data available in the logger will display in the start date/time and end
date/time fields adjacent to the Read Data Between radio button.
Read Since Last Selecting this option reads back all data since the
last readback for the selected logger.
Read Data Between Selecting this option allows the user to
designate the date/time range for which to readback the data from the
logger. If the logger configuration has just been read, the range of data
available in the logger will display in the corresponding start date/time
and end date/time fields. Designate the start and end dates/times using
the data selection tool accessible by clicking on the down arrows
associated with each date/time field.
Current Values
Selecting this checkbox expands the dialog to reveal additional data fields.
These fields are filled with current values from the data logger. These values
will update every 10 seconds.