4 COMMISSIONING
The power supply connection and interfaces of this device are installed inside the case.
You have to remove the case cover in order to connect the power supply cables and the
interface cables.
All supply leads and all required data leads have to be connected before commissioning.
Warning:
The device must be switched off before connecting or disconnecting any cables in order
to prevent damage to the electronics!
The device may only be switched on after acclimatising to the ambient temperature in
order to avoid condensate accumulation. Make sure to meet the admissible voltage
requirements for this device.
After switching off and before switching on you must wait for at least 5 seconds.
Note:
The screen of a data cable must always be connected with the connector housing (EMC).
Under the embedded operating system, interfaces must explicitly be enabled and required
drivers must be installed in order to be able to use them.
4.1 AVAILABLE INTERFACES
Pos: 17 /Datentechnik/ Inbetriebnahme/ Kabelmontage/Kabe lmontage für VMT-Seri e / MSA 5012 / 5015 @ 0\mod_11588479318 66_681.doc @ 798 @
Hinweis:
The device can be started with the ignition function.