SDS
  Page 3 of 5 
8.  EXPOSURE CONTROLS – PERSONAL PROTECTION 
Engineering Control: 
Local ventilation recommended when handling. 
Control Parameters: 
Time weighted average for 8-hour shift (TWA) – No data 
 Short Term Exposure Limit (STEL) – No data 
 Ceiling – No data 
 Biological Exposure Index (BEI) – No data 
Respiratory Protection: 
Though the smoke and odor generated by hot melting glue is not toxic, each 
person has different sensitivity tolerances, it is recommended to wear a 
mask. 
Personal Protective 
Equipment: 
Hand protection – heat insulated gloves  
Eye protection – safety goggles 
Skin protection – wear long-sleeved or protective clothing. 
Sanitary Measures: 
No specific requirements. 
9.  PHYSICAL AND CHEMICAL PROPERTIES 
Physical State: 
Solid 
Olfactory Threshold: 
Not applicable 
pH: 
7.8 
Flash Point: 
Over 392°F / 200°C 
Test Method: 
Open cup 
Auto-ignition 
Temperature: 
Not applicable  
Specific Gravity: 
.98 (H2O=1 @ 4°C) 
Evaporation Rate: 
Not applicable 
Odor: 
Resin 
Softening Point: 
185±10°F (85±5°C) 
Boiling Point:  
Not applicable 
Flammability: 
Not applicable 
Decomposition 
Temperature: 
Not applicable 
Explosion Limit: 
Not applicable 
Water Solubility:  
Insoluble 
Octanol / Water 
Partition Coefficient 
(Low Kow):   
Not applicable  
Color: 
Clear 
Viscosity:     
8,800 -11,800 cps @ 350°F   
10.  STABILITY AND REACTIVITY 
Stability: 
Stable 
Polymerization: 
Hazardous polymerization will not occur. 
Incompatibilities –
Materials to avoid: 
Strong oxidizing agents. 