User manual
 ADT-TP3340DJ Three-axis Dispenser 
- 13 - 
1)  File parameter setting 
Start dispensing speed: During processing, the running speed when the glue gun is opened 
is the dispensing speed, and the speed when the glue gun isn’t opened is the space shift speed (or 
quick orientation speed). The motor must start with low speed and then accelerate to the running 
speed. If the start speed is too low, the acceleration time will be long; if the start speed is too high, 
the motor may be out of step. 0% corresponds to the “Minimum speed” of the motor, while 100% 
corresponds to the “Maximum start speed”. 
Dispensing acceleration: The higher the acceleration is, the shorter the time from start 
speed accelerated to running speed and the time from running speed decelerated to stop are; 
otherwise, the longer the time is.  
Dispensing speed: During processing, the running speed when the glue gun is opened is the 
dispensing speed, and the speed when the glue gun isn’t opened is the space shift speed (or quick 
orientation speed). 0% corresponds to the minimum speed of XY-axis, while 100% corresponds 
to the maximum speed of XY-axis. 
Gun opening delay: The time (unit: sec) from the glue gun receiving open signal to totally 
opened 
Gun closing delay: The time (unit: sec) from the glue gun receiving close signal to totally 
closed 
Advance closing distance: After dispensing, close the glue in advance to avoid glue 
accumulated in the stopping position. 
Processing quantity setting, automatic process interval: When the specified quantity has 
been processed, the machine stops processing automatically, and continues processing 
automatically if not. The interval is determined by the automatic processing interval. 
Automatic resetting times setting: After processed specified times, the motor resets to 
eliminate accumulated error. 
Present quantity: Present processing quantity; when this quantity reaches specified value, 
the machine stops and resets automatically. 
Present total output: The accumulated output 
2)  Glue gun operation setting 
In each station, you can set the glue guns opened in initial state by setting the glue gun to 
“Use”. 
3)  Start processing point setting 
After editing a file, if you find that the running track of certain station has overall shift from 
required track, you can solve this problem by setting the start processing point, i.e. correspond the 
set start point to the first processing point of the processing file, and shift other processing points 
according to this offset. If two stations have same offset, you can use the “Modify” function in 
instruction view. 
Station I file parameter settings 
File parameter setting Glue gun usage setting
Station I processing start setting 
Save as default  Restore default Back 
Station I glue gun setting 
Glue gun I: Use Glue gun V: Not use 
Glue gun II: Not use   Glue gun IV: Not use 
Glue gun III: Not use Glue gun IIV: Not use 
Glue gun IV: Not use Glue gun IIIV: Not use 
Page: 01/01 OK Cancel 