User manual
 ADT-TP3340DJ Three-axis Dispenser 
- 5 - 
(Single station worktable)  (Double-station worktable) 
This system supports two processing modes: single station and double stations. The information 
of the processing file appears in workstation info display area. 
Prompt: In “Manufacturer parameter settings” -> “System configuration”, you can select single 
station or double-station for “Station number”. If double-station is selected, you also need to 
select same Y-axis or different Y-axis in “Y-axis configuration for double-station” (if the Y-axes 
of two stations act simultaneously, select “Same Y-axis”; if not, select “Different Y-axes”), and 
then turn on/off a station in “Double-station switch” in User parameter settings“. 
2.  Processing state display bar: 
The processing states include “Stop”, “Run”, “Pause”, “Reset”, “Emergency stop”, “Automatic 
dispensing” and “Error”. 
3.  Real-time coordinates display area: 
The unit is millimeter (mm), where U-axis is the coordinates of second Y-axis of double-station. 
4.  Processing operation buttons: 
The operations such as start, reset, pause and stop have corresponding buttons; 
For automatic dispensing function, you need to set the “Automatic tackless time” and “Automatic 
tackless interval” in “User parameter settings” -> “Delay settings”. If one or two of the parameters are 
set to 0, the automatic dispensing function is invalid. 
The AUTO/Single Step button allows the controller running in automatic or single step mode. In 
automatic mode, the program runs once from the start to the end and stops; in single step mode, the 
program executes one instruction when you press the Start key. The single step function is mainly used 
for files test. 
5.  Function menu buttons: 
“Parameter settings” is used to set the parameters. Enter the password to access corresponding 
interface, including manufacturer settings, user parameter settings, file parameter settings and 
password management; 
“Hardware test” is used for the test of the control system, including input, output and motor 
control; 
“File manager” is used to manage the files in local disk, mobile disk and remote device, and you 
can perform operations like copy, delete, new file and preview. 
II. Parameter settings 
Enter the password to access the corresponding interface: 