User manual
   ADT-HC4500 CNC Flame/Plasma Controller 
61
Picture 4.5 Accuracy parameter interface 
4.5.1 Pulse equivalent setting 
1) In main interface, press [F4] and then [F5] to enter the accuracy setting interface, and set 
the X and Y pulse equivalent as 
0.010000 (at this time, the control system gives a pulse and the motor moves 0.01MM). 
After the setting, press [F6] to save and exit to the main interface. 
2) Press [F1] and then [F2] to enter the manual interface, and then press [F1] again when “Inching 
increment: L=+00000.000” will show up 
Input the required length of inching, suppose setting the inching unit as 1000MM 
3) Press any key of [X+] [X-] or [Y+] [Y-] to start inching. Suppose the actual moving distance is 
578MM 
Calculation formula: (578 × 0.01) ÷ 1000 = 5.78 ÷ 1000 = 0.005780 
1)  Back to the main interface, press [F4] and [F5] to enter the accuracy setting interface, and 
input 0.005780 as the pulse equivalent of X and Y axes. 
      Note: Usually, there will be a minor error between the pulse equivalent of X and Y of the same device; 
therefore, they should be set respectively during the test. 
Actual inching 
distance 
Actual moving 
distance 
Pulse equivalent 
of current system 