User manual
   ADT-HC4500 CNC Flame/Plasma Controller 
62
4.6 Save 
    You should press [F6] once every time when the value of a submenu in “Parameter” is modified; otherwise, 
the modified value would not be saved. 
5. Diagnosis (Diag) 
Press [F5] in main interface, and the system will enter the diagnosis interface as Picture 2.6 below: 
Picture 5 Diagnosis interface 
5.1 Sub-menu 
 1) Diagnosis interface 
In diagnosis interface as Picture 5, press [F1] to enter the diagnosis testing interface as Picture 
5.1.1: 
Operating instructions: 
[F1]: Test the positive rotation of X axis 
[F2]: Test the contrarotation of X axis 
[F3]: Test the positive rotation of Y axis 
[F4]: Test the contrarotation of Y axis 
[F5]: Stop the current X/Y rotation 
You can press [X+], [X-], [Y+], or [Y-] to move the output cursor, and then press OK to output 
the relevant switching signal. 
If there is an input signal, a ‘*’ will show below the relevant pin sign of input diagnosis. 










