   ADT-HC4500 CNC Flame/Plasma Controller 
89
ZDR-
XDR-
5V-
ZDR+
5V-
XDR+
YDR-
XPU-
PU_COM
XS3
8
15
7
14
6
13
5
12
4
11
3
10
2
9
1
ZPU+
ZPU-
XPU+
YDR+
YPU-
YPU+
Line S/N  Name  Function 
1  XDR+  X direction signal + 
9  XDR-  X direction signal - 
2  XPU+  X pulse signal + 
10  XPU-  X pulse signal - 
3  YDR+  Y direction signal + 
11  YDR-  Y direction signal - 
4  YPU+  Y pulse signal + 
12  YPU-  Y pulse signal - 
5  ZDR+  Z direction signal + 
13  ZDR-  Z direction signal - 
6  ZPU+  Z pulse signal + 
14  ZPU-  Z pulse signal - 
7  PU_COM  Internal 5V positive, not allowed to connect the external 
power supply (for driver with single-end input) 
15  5V-  Internal 5V negative, not allowed to connect the external 
power supply 
8  5V-  Internal 5V negative, not allowed to connect the external 
power supply 