User manual
   ADT-HC4500 CNC Flame/Plasma Controller 
94
14  OUT8  Cutting Oxygen / Plasma (arcing) control , M12 (Open), 
M13 (Closed) 
15  OUT9  Cutting gun falling control, M16 (Open), M17 (Closed) 
16  OUT10  B ackup , M18 (Open), M19 (Closed) 
17  OUT11  Flame cutting Preheating oxygen valve control, M24 
(Open), M25 (Closed) 
18  OUT12  Backup preheating oxygen control, M26 (Open), M27 
(Closed) 
19  OUT13  Backup Oxygen/arcing cutting control, M32 (Open), M33 
(Closed) 
20  OUT14  Backup cutting gun falling control, M36 (Open), M37 
(Closed) 
21 OUT15 {Flame} Torch Height control, M42(open), 
M43(close) 
22 NC Null 
23 NC Null 
24  +24V  Internal 24V+ of controller (do not connect any circuit) 
25 GND 0V 
Connection mode of output signal: 
The output is the open-collector output, if the external load is inductive load such as relay; a freewheeling 
diode should be connected, as the following picture shows: 
EXTCOM is connected to the negative end of internal power supply, and the output signal is connected to 
the relevant terminal. 
EXTCOM OR 
DOUTnGND 