Datasheet

jobAid
DESCRIPTION
TheOC12SmallFormFactorPluggableCWDM1491nm(SFP
OC12)plugsintoADTRANOC12equipmentdesignedtoaccept
SmallFormfactorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC12providesan
OC12CWDMinterfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC12:
SONETOC12compatible(622.08Mb/s)1491nm,
longreach,singlemode,2fiberoperation
80kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonly SFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
OpticalSpecifications:
Opticaltransmitlevel:–3dBmto+5dBm
Opticalreceivelevel:–28dBmto–8dBm
Powerpenalty:–1dB
Opticalbudget:24(±1)dBm
Minimumspanattenuation:13dB
Opticalconnectors:LC
ExtendedEnvironmentalSupport:
Operationaltemperaturerange:–40°Cto+65°C
Storagetemperaturerange:–40°Cto+85°C
Relativehumidityto95%,noncondensing
OC-12 Small Form-Factor Pluggable
CWDM 1491 nm
INSTALLATION
ToinstalltheSFPOC12intoanappropriatemodule,complete
thefollowingsteps:
1. InspecttheSFPOC12.Ifdamaged,fileaclaimwiththecar
rierandthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC12intotheSFPcageonthemodule.
EnsurethatthemanufacturerslabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheSFPOC12allthewayintothereceptacleuntil
thereisanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC12 is not directly provisionable. To provision the
SFPOC12, access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M
provided with the host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDisc harge (ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccom pon ents .Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
wor kin g on modules, always placethem on an approved
antistaticmatthatiselectricallygrounded.
TheSFPOC12isNRTLListedtotheapplicableULstandards.
TheSFPOC12meetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR63CORE,GR1089CORE,andETSIEN
300368.
TheSFPOC12isintendedfordeploymentin
CentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC12istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SOOTAKNJ_ _
Product P/N: 1442703PG2
Issue Date: December 2010
Document P/N: 61442703PG2-22B

Summary of content (2 pages)