Specifications

1 61180001L1-5B Section 61180001L1-5 Issue 2
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Total Access
TM
1500 Chassis
Installation and Maintenance
Section 61180001L1-5B
Issue 2, March 2001
CLEI Code #VAMMKJOE_ _
Figure 1. Total Access 1500 Chassis
1. GENERAL
This practice provides installation and maintenance
procedures for the ADTRAN Total Access 1500
(Total Access 1500) Chassis. Figure 1 is an
illustration of the Total Access 1500 Chassis. Part
number for equipment and documents referenced in
this practice are located in the Specifications Table.
Referenced practices should be on-hand during system
installation.
Revision History
This is the second release of this document. Alarm
information for quad T1 mode has been added, and
information regarding connection to Pair Gain Test
Controller (PGTC) has been added.
Features
The Total Access 1500 Chassis, part number
1180001L1, features include the following:
Rackmount design
Scalable Network Connectivity
-1-4 T1 capacity
Protect T1 for TR-08 applications
Three common units:
-Power Supply/Ring Generator (PSU/RGU)
-System Controller Unit (SCU)
-Line Interface Unit (LIU)
T1 Network Interface
24 slots for combination of voice and data
services
Variety of access module units
Network management capabilities - TL1, SNMP
Multiple configuration arrangements
TR-08 Compatible (Modes 1 and 3)
Supports Mechanized Loop Testing (MLT)
FCC and UL 1950 compliant
Meet NEBS Level 3 requirements
General Description
The Total Access 1500 Chassis is designed to meet a
variety of operating configurations and services, such
as POTS, Special Services, and xDSL. The Total
Access 1500 is intended for use in central office and
remote terminal applications. The Total Access 1500
System is comprised of the chassis, common cards,
and access modules.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
CONTENTS
1. GENERAL .................................................................... 1
2. INSTALLATION.......................................................... 2
3. MAINTENANCE ....................................................... 12
4. WARRANTY AND CUSTOMER SERVICE ........... 12
FIGURES
Figure 1. Total Access 1500 Chassis .................................. 1
Figure 2. Power and Ground Connectors ........................... 4
Figure 3. Total Access 1500 Backplane and Pin-outs ........ 5
Figure 4. Composite Clock Wiring ..................................... 8
Figure 5. Alarm Contacts .................................................... 9
Figure 6. RS-485 Wiring................................................... 11
TABLES
Table 1. Compliance Codes ................................................ 3
Table 2. Total Access 1500 Specifications ....................... 12
HST
MLT
BSY
MJR
T
I
M
I
N
G
C
R
A
F
T
MNR
RMT
ACO
A
C
P
YEL
REM
MASTER
R
D
RED
RCV
TEST
STATUS
TX
MONITOR
RX
A
C
P
YEL
REM
MASTER
R
D
RED
RCV
TEST
STATUS
TX
MONITOR
RX
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP
STATUS
REM
AP

Summary of content (12 pages)