NetVanta 6240 Series IP Business Gateways Hardware Installation Guide 61700202G1-34A April 2011
Trademarks NetVanta 6240 Series Hardware Installation Guide Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.
NetVanta 6240 Series Hardware Installation Guide Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 61700202G1-34A Copyright © 2011 ADTRAN, Inc.
Safety Instructions NetVanta 6240 Series Hardware Installation Guide Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm. There is a remote risk of shock from lightning.
NetVanta 6240 Series Hardware Installation Guide FCC-Required Information FCC-Required Information FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of Federal Communications Commission (FCC) rules and requirements adopted by America’s Carriers Telecommunications Association (ACTA). Each registered interface has a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX.
FCC Radio Frequency Interference Statement NetVanta 6240 Series Hardware Installation Guide FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front Panel Design . . . . . . . . . . . . .
Table of Contents 8 NetVanta 6240 Series Hardware Installation Guide Copyright © 2011 ADTRAN, Inc.
List of Figures Figure 1. Figure 2. Figure 3. Figure 4. NetVanta 6240 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 6240 Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wallmount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wall Mounting the BBU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Figures 10 NetVanta 6240 Series Hardware Installation Guide Copyright © 2011 ADTRAN, Inc.
List of Tables Table 1. Table 2. Table A-1. Table A-2. Table A-3. Table A-4. Table A-5. Front Panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BBU Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VOICE Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FXO Connector Pinouts . . . . . .
List of Tables 12 NetVanta 6240 Series Hardware Installation Guide Copyright © 2011 ADTRAN, Inc.
1. INTRODUCTION This hardware installation guide describes the NetVanta 6240 Series units’ physical characteristics, lists their features and specifications, introduces basic functionality, and provides installation instructions.
Physical Description 2. NetVanta 6240 Series Hardware Installation Guide PHYSICAL DESCRIPTION The NetVanta 6240 Series are multiservice Internet Protocol (IP) business gateways designed for use in integrated voice and data service offerings to small-to-medium sized businesses worldwide. This product line is a high-bandwidth business gateway designed to allow carriers to deliver up to 60 channels of Voice over IP (VoIP) to their customers.
NetVanta 6240 Series Hardware Installation Guide Physical Description Table 1. Front Panel LEDs LED Color STATUS VOICE NET 1 through NET 4 LAN 1/LAN 2 Indication Off Unit is not receiving power. Green (flashing) On power up, the STATUS LED flashes rapidly for five seconds, during which time the user may escape to boot mode from the CONSOLE port. Green (solid) Power is on and the unit is functioning normally. Amber (solid) Power has failed and the unit is in battery backup mode.
Physical Description NetVanta 6240 Series Hardware Installation Guide Network Interfaces The NET 1 T1 0/1 through NET 4 T1 0/4 interfaces are DS1 RJ-48C pin connections. See Table A-3 on page 28 for the network interface pinouts. The status LEDs, labeled NET 1 through NET 4, are located on the front panel. 10/100Base-T Ethernet Interfaces The ETH 0/1 and ETH 0/2 ports are RJ-45 connectors. See Table A-4 on page 28 for the Ethernet interface pinouts.
NetVanta 6240 Series Hardware Installation Guide 3.
Unit Installation 4. NetVanta 6240 Series Hardware Installation Guide UNIT INSTALLATION The instructions and guidelines provided in this section cover hardware installation topics, such as mounting options and supplying power to the unit.
NetVanta 6240 Series Hardware Installation Guide Unit Installation Mounting Options The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide step-by-step instructions for rack mounting and wall mounting. Rack Mounting the NetVanta The NetVanta is a 1U-high, rack-mountable unit that can be installed into a 19-inch equipment rack. The following steps guide you in mounting the NetVanta into a rack.
Unit Installation NetVanta 6240 Series Hardware Installation Guide Wall Mounting the NetVanta By following these instructions exactly, the NetVanta can be safely mounted on the wall. • • • To avoid damaging the unit, use only the screws included in the shipment when attaching mounting ears to the chassis. When wall mounting the NetVanta, care must be taken not to damage the power cord. Do not attach the power cord to the building surface or run it through walls, ceilings.
NetVanta 6240 Series Hardware Installation Guide Unit Installation Figure 3. Wallmount Installation 61700202G1-34A Copyright © 2011 ADTRAN, Inc.
Unit Installation NetVanta 6240 Series Hardware Installation Guide Supplying Power to the Unit The NetVanta 6240 Series units come equipped with a 120 VAC, 60 Hz power supply for connecting to a properly grounded power receptacle. (A detachable power cable with a grounded, three-prong plug comes with the shipment.) To power this unit, connect the power cable to an appropriate AC power source.
NetVanta 6240 Series Hardware Installation Guide Unit Installation Unpack and Inspect the BBU After unpacking the BBU unit, inspect it for damage. If damage is noted, file a claim with the carrier; then contact ADTRAN Customer Service. Batteries are retained and prewired in the BBU in a specific pattern. Battery position is maintained by foam spacers press fitted against the housing walls. Removing batteries or disconnecting wires compromises correct reassembly and should not be attempted.
Unit Installation NetVanta 6240 Series Hardware Installation Guide Install the BBU as follows: Instructions for Wall Mounting the BBU Step Action 1 Decide on a location for the BBU, keeping in mind that the cable plugs must be able to reach their designated sockets in the NetVanta unit. 2 Prepare the mounting surface by attaching a board (typically plywood, 3/4-inch to 1-inch thick) to a wall stud using #6 to #10 (2.5-inch or greater in length) wood screws.
NetVanta 6240 Series Hardware Installation Guide Unit Installation BBU Specifications Table 2 provides BBU specifications. Table 2. BBU Specifications Battery Part Number: Suppliers: Batteries: Voltage: Backup Time: Wire Gauge: 311212V02 YUASA and Panasonic 7 AHR per battery -12 VDC per battery Up to 8 hours 18 AWG Environmental Operating Temperatures: Preferred: Charge: -15°C to 50°C Discharge: -20°C to 60°C 20°C Physical Dimensions P/N 1175044L1: Weight: 17-inch W x 6.5-inch H x 3.
Unit Installation 26 NetVanta 6240 Series Hardware Installation Guide Copyright © 2011 ADTRAN, Inc.
APPENDIX A. CONNECTOR PIN DEFINITIONS The following tables provide the pin assignments for the base unit. Table A-1.
Appendix A NetVanta 6240 Series Hardware Installation Guide Table A-2. FXO Connector Pinouts Pin Name Description 1, 2 — 3 Ring 4 Tip Tip lead of the 2-wire interface 5, 6 — Unused Unused Ring lead of the 2-wire interface Table A-3. T1 Port Pinouts Pin Name Description 1 RX Receive data from the network–Ring 2 RX Receive data from the network–Tip 3 — Unused 4 TX Transmit data toward the network–Ring 5 TX Transmit data toward the network–Tip 6-8 — Unused Table A-4.
Index Numerics P 10/100Base-T Ethernet interfaces 16 command line interface 18 craft interface 16 physical description 14 pinouts 10/100Base-T ports 28 craft port 28 FXO ports 28 T1/E1 ports 28 voice port 27 power battery backup unit 16 connection 16 internal supply 16 supplying to unit 22 product registration 6 product specifications 17 F R B battery backup unit 16 features 22 maintenance 24 recycling batteries 24 safety instructions 23 specifications 25 wall mounting instructions 24 C features 17
Index 30 NetVanta 6240 Series Hardware Installation Guide Copyright © 2011 ADTRAN, Inc.