Instruction manual
Total Access 850 System Manual Section 4 User Interface Guide
64203376L1-1B © 2004 ADTRAN, Inc. 103
INTERFACES (FXS)
View the FXS interface status and configure the FXS parameters from this menu.
INTERFACES (FXS) > CONFIG
Configure the FXS mode, line impedance and Tandem parameters from this menu.
INTERFACES (FXS) > CONFIG > SLOT
Displays the slot number associated with the installed FXS Module.
INTERFACES (FXS) > CONFIG > PORT
Indicates the port on which the FXS is installed.
INTERFACES (FXS) > CONFIG > MODE
Choices are given below. Default is LOOP START.
This mode must match the network configuration and/or how each port is being used. Each
port on the FXS Module is independent and should be set accordingly.
LOOP START
Sets the port to use FXS loop start signaling on the T-span and loop start
supervision on the analog 2-wire interface.
GROUND START
Sets the port to use FXS ground start signaling on the T-span and ground
start supervision on the analog 2-wire interface.
PLAR
Sets the port to use Private Line, Automatic Ringdown signaling on the
analog 2-wire interface. When one end of a PLAR circuit goes off-hook,
the other end automatically rings. PLAR circuits are point to point
between two interfaces.
TR08 SINGLE
Sets the port to use Single Party Channel Unit signaling on the T-span
(as defined by TR-TSY-000008) and loop start supervision on the
analog 2-wire interface.
TR08 UVG
Sets the port to use Universal Voice Grade signaling on the T-span (as
defined by TR-TSY-000008) and either loop start or ground start
supervision on the analog 2-wire interface.
DPO
Sets the port to use Dial Pulse signaling to originate dialed numbers.
TANDEM (E&M)
Sets the port to use E&M signaling on the T-span and either loop start or
ground start supervision on the analog 2-wire interface. See the
TANDEM
submenus for more information.