Instruction manual

Total Access 850 System Manual Section 4 User Interface Guide
64203376L1-1B © 2004 ADTRAN, Inc. 107
INTERFACES (FXO)
View the FXO interface status and configure the FXO parameters from this menu.
INTERFACES (FXO) > CONFIG
Configure the FXO mode, line impedance, and Tandem parameters from this menu.
INTERFACES (FXO) > CONFIG > SLOT
Displays the slot number of the installed FXO Module.
INTERFACES (FXO) > CONFIG > PORT
Indicates the port on which the FXO is installed.
INTERFACES (FXO) > CONFIG > MODE
Choices are given below. Default is LOOP START.
INTERFACES (FXO) > CONFIG > TX (dB)
Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal
that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this
number should be increased. A higher number indicates more attenuation which equals lower volume. The
value entered must be less than 10 dB. Default is
0.0 dB.
INTERFACES (FXO) > CONFIG > RX (dB)
Sets the RX direction level points. This signal will change the volume of the voice. A higher number
indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default
is
0.0 dB.
This mode must match the network configuration and/or how each port is being used. Each
port on the FXO Module is independent and should be set accordingly.
LOOP START
Sets the port to use FXO loop start signaling on the T-span and loop
start supervision on the analog 2-wire interface.
GROUND START
Sets the port to use FXO ground start signaling on the T-span and
ground start supervision on the analog 2-wire interface.
DPO
Sets the port to use Dial Pulse signaling to originate dialed numbers.
MODIFIED DPT
Sets the port to use DPT signaling on the interface. In DPT mode, digits
are transmitted out the FXO interface to the user equipment. DPT mode
is one-way operation only (outbound calls only).