Instruction manual

Section 4 User Interface Guide Total Access 850 System Manual
108 © 2004 ADTRAN, Inc. 64203376L1-1B
INTERFACES (FXO) > CONFIG > SVC MODE
Indicates whether the module is IN SERVICE or OUT OF SVC. This does not indicate whether the port has
been mapped. For proper operation, the port must be mapped using the
DS0 MAPS menu. Default is IN
S
ERVICE.
INTERFACES (FXO) > STATUS
Displays the status of the FXO signal bits.
INTERFACES (FXO) > STATUS > SLOT
Displays the slot number for the installed FXO Module.
INTERFACES (FXO) > STATUS > PORT
Displays the port number.
INTERFACES (FXO) > STATUS > TA SIG
This parameter displays the status of the Transmit A signal bit. The high/low status is indicated by a 0 or 1.
INTERFACES (FXO) > STATUS > TB SIG
This parameter displays the status of the Transmit B signal bit. The high/low status is indicated by a 0 or 1.
INTERFACES (FXO) > STATUS > RA SIG
This parameter displays the status of the Receive A signal bit. The high/low status is indicated by a 0 or 1.
INTERFACES (FXO) > STATUS > RB SIG
This parameter displays the status of the Receive B signal bit. The high/low status is indicated by a 0 or 1.
INTERFACES (FXO) > TEST
Activate tests and monitor test status on a per port basis from this menu.
INTERFACES (FXO) > TEST > SLOT
Displays the slot number for the installed FXO Module.
INTERFACES (FXO) > TEST > PORT
Displays the port number.