Total Access 850 System Manual Section 4 User Interface Guide
64203376L1-1B © 2004 ADTRAN, Inc. 109
INTERFACES (FXO) > TEST > TEST
Choices are given below. Default is NONE.
INTERFACES (FXO) > TEST > TEST STATUS
This option indicates whether a test is in progress.
INTERFACES (DSX-1 MODULE)
View the DSX-1 Module interface status and configure the DSX-1 Module parameters from this menu.
INTERFACES (DSX-1) > CONFIG
Configures the DSX-1 interface format and code from this menu.
INTERFACE (DSX-1) > CONFIG > SLOT
Indicates the slot in which the DSX-1 Module is installed.
INTERFACE (DSX-1) > CONFIG > PORT
Indicates the port on which the DXS is installed.
INTERFACE (DSX-1) > CONFIG > FORMAT
This setting must match the frame format of the circuit to which the interface is connected. Choices are
ESF and SF (D4). Extended Superframe (ESF) provides a non-disruptive means of full-time monitoring on
the facility data link (FDL). The default is
ESF.
NONE
Indicates that no test is currently active.
DIGITAL NETWORK
L
PBK
Used to loop back DS0 data coming from the network for each channel.
Received data is latched in on the appropriate receive time slot on the
receive bus. This data is then placed on the transmit bus in the unit’s
transmit time slot.
NETWORK ON HOOK
T
EST
Used to test signaling sent to the network by the unit. On-hook signaling
is sent to the network. The customer loop is forced on-hook while this
test is active.
NETWORK OFF HOOK
T
EST
Used to test signaling sent to the network by the unit. Off-hook signaling
is sent to the network. The customer loop is forced off-hook while this
test is active.
1004 HZ - 0DCBM0
T
ONE GEN
Used to verify talk path by sending out 1004 Hz tone to test across the
network. Monitoring of the T1 as well as the Far-End 2-wire side
verifies the talk path if the tone is heard.