INTERFACE (UBR1TE) > CONFIG > SEALING CURRENT
DC sealing current is only applicable if the mode is LULT. Sealing current should be present for
Adjacent-to-Customer applications. Default is
ENABLED.
INTERFACE (UBR1TE) > STATUS
View the interface status information for the UBR1TE Module.
INTERFACE (UBR1TE) > STATUS > SLOT
Displays the slot number for the installed UBR1TE Module.
INTERFACE (UBR1TE) > STATUS > ACT BIT
This status field indicates whether an NT1 is communicating with the ISDN switch.
INTERFACE (UBR1TE) > STATUS > LOOP
Displays synchronization between the UBR1TE card and the NT1 on the loop side of the card. Sync
displays
YES or NO.
INTERFACE (UBR1TE) > STATUS > CARRIER
Displays synchronization between the ISDN switch and the UBR1TE card on the T1 network side. Sync
displays
YES or NO.
INTERFACE (UBR1TE) > STATUS > RX LOOP CRC ERROR
Indicates a CRC error has been received on the loop side of the card (indicating it came from the NT1).
INTERFACE (UBR1TE) > STATUS > RX CARRIER CRC ERROR
Indicates a CRC error has been received on the carrier side of the card (indicating it came from the ISDN
switch).
INTERFACE (UBR1TE) > STATUS > TEST STATUS
Indicates whether a test is in progress.
INTERFACE (UBR1TE) > TEST
These options are used to initiate tests.
INTERFACE (UBR1TE) > TEST > SLOT
Displays the slot number for the installed UBR1TE Module.
INTERFACE (UBR1TE) > TEST > B1 TEST
Initiates a test on the first B channel (B1) of the ISDN circuit. The following tests are available:
NONE No active test.