Section 4 User Interface Guide Total Access 850 System Manual
182 © 2004 ADTRAN, Inc. 64203376L1-1B
4. APPENDICES (T1 TDM APPLICATIONS)
Appendix A. Configuring the Unit for Routing
Initial Setup
It is best to configure Total Access 850 TDM applications by following the order of the top-level menus.
For example, first configure the system parameters using the
SYSTEM INFO and SYSTEM CONFIG menus.
Next, configure the Layer 1 parameters using the
INTERFACES menu. Once the Layer 1 information is
configured, proceed to the Layer 2 setup using the
L2 PROTOCOL menus. Follow the Layer 2 setup with the
data “routing” menus (either
BRIDGE or ROUTER). Establish packet forwarding and blocking using the
SECURITY menus. Lastly, configure the physical mappings using the DS0 MAPS menus.
The following example provides step by step instructions for configuring the Total Access 850 T1 TDM
system (
INTERFACES through DS0 MAPS) for a standard routing application. System Info and System
Config parameters should be set according to your system need. Refer to System Info on page 73 and
System Config on page 75 for more details.
1. Setting up the Interfaces
For more details on the configuration parameters discussed in this section, refer to the following pages:
Network T1 menus beginning on page 94
Ethernet menus beginning on page 101
T1 Interface Setup Instructions
Step Action
1
From the main menu, select INTERFACES.
2
Highlight the CONFIG menu for the T1 interface and press <ENTER>.
3
Right arrow to select FORMAT and choose ESF or SF.
This format must match the format used by the other units in the network.
4 Set the LINE CODE to B8ZS or AMI.
This line code must match the line code used by the other units in the network.
5
Set the EQUALIZATION or line build out. The default setting of 0 DB is usually
sufficient.
6
Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on
whether looping to this unit from another unit will be allowed.