FXS Interface Setup Instructions
Step Action
1 From the main menu, select I
NTERFACES.
2
Highlight the CONFIG menu for the FXS interface and press <ENTER>.
3
Right arrow to select MODE and choose LOOP START, GROUND START, TANDEM
(E&M), TR08 S
INGLE, TR08 UVG, or DPO.
This mode should be set based on the network configuration and the operation
of each FXS port. All FXS ports are independent and do not need to have the
same mode.
4
Set the T
X (dB) or transmit direction level for each port. The default value is
recommended.
5
Set the R
X (dB) or received direction level for each port. The default value is
recommended.
6 Set the S
VC MODE to IN SERVICE to activate the port.
7
Set the L
INE Z (line impedance) of each port based on the size of the network.
The default value is recommended.
8
Set the M
SG IND to DISABLE or ENABLE. When set to ENABLE, talk path is
always open, even in on-hook conditions, in order for FXS message tones to
pass through. Disabling this feature will allow higher on-hook voltage but will
not allow on-hook messaging other than caller ID.
9
Configure the on-hook battery voltage using the B
ATT MODE field. For most
IAD installs, the FXS loop is short with 6 to 7 V present on tip / ring. To reduce
power dissipated during off-hook conditions, the battery is lowered for short
loop lengths. When set to A
UTO SWITCH, the IAD uses a higher on-hook
battery voltage (48-52 V). When off-hook, it automatically switches to low
battery (24-26 V) to minimize power dissipation. When set to L
OW BATTERY
mode, the higher battery is not used and the voltage is a constant 26 V even
while on-hook. The tip/ring voltage is reduced to 26 V when using the L
OW
B
ATTERY mode.
10
Specify the interval of battery removal during a forward disconnect state
using the F
WD DISC TIMER field. Choices are FOLLOW SWITCH (default), 500MS,
750
MS, 1000MS, and 2000MS. When using ATM mode, there is an additional
choice of I
GNORE SWITCH. If the timer is set to FOLLOW SWITCH, the
Total Access 850 will follow the switch at all times; this is normal operation. If a
time period has been selected, the Total Access 850 will remove battery for
the specified time period OR as long as the switch requests battery removal,
whichever is longer. For example, if the timer expires but the switch continues
to request battery removal, the Total Access 850 will follow the switch and
continue to remove battery. For ATM mode, if the timer is set to I
GNORE
S
WITCH, the IAD will never remove battery.