64203376L1-1B © 2004 ADTRAN, Inc. 221
DLP-4 Verifying Communications Over an IP LAN
Introduction
When the Ethernet port is connected to a local area network (LAN), test steps must be performed on the
Total Access 850 to ensure that the unit is communicating properly over the network. This procedure
outlines those steps.
Prerequisite Procedures
Before beginning this procedure, the unit should be physically connected to the LAN and the provisioning
tasks detailed in DLP-3, Setting IP Parameters for the Total Access 850, should be complete.
Tools and Materials Required
• Access to a PC or other computer connected to the LAN
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling
modules, put on an antistatic discharge wrist strap to prevent damage to electronic
components. Place modules in antistatic packing material when transporting or storing.
When working on modules, always place them on an approved antistatic mat that is
electrically grounded.