Instruction manual

Section 5 DLP-17 Total Access 850 System Manual
266 © 2004 ADTRAN, Inc. 64203376L1-1B
1. Connect the Total Access 850 unit to your VT100 system (details found in DLP-1, Connecting a VT100
Terminal or PC to the CRAFT Port).
2. Log in to the system with maximum rights (details are in DLP-2, Logging in to the System).
3. From the DS0 M
APS menu, select the ACTIVE MAP option and press <Enter>.
4. From the DS0 M
APS > ACTIVE MAPS menu, select the DUAL T1 MAP option; press <Enter>. Select “Y”
for yes to confirm the Active Map change and press <Enter>. The following screen appears.
Figure 1. Dual T1 Map
Perform the steps below in the order listed.
The second T1 connected to the DSX port may only be used for voice connections
(FXS/FXO). The second T1 must be connected to the integrated DSX port, not the DSX-1
Card.