Instruction manual
Section 2 Engineering Guidelines Total Access 850 System Manual
32 © 2004 ADTRAN, Inc. 64203376L1-1B
SDSL Router Controller Unit (1200377L1 and 1200377L2)
The following is operational information pertaining to the SDSL Router Controller Unit when used with
the Total Access 850 system.
Faceplate CRAFT Interface
Use the CRAFT port on the RCU faceplate to configure the system via an EIA-232 connection. Table 7
displays the
CRAFT port pinout.
Faceplate LEDs
The faceplate LEDs provide status information using a color coded message format. Table 8 gives a
description of all faceplate LEDs for the SDSL RCU when used with the Total Access 850 system.
Table 7. SDSL RCU CRAFT (DB-9, Female) Pinout
Pin Name Description
1, 4, 6-9 UNUSED —
2RDReceive Data (Output)
3TDTransmit Data (Input)
5SGSignal Ground
Table 8. SDSL RCU Faceplate LEDs
For these LEDs... This color light... Indicates that...
PWR OFF there is no power to the system.
Solid GREEN the system is connected to an active power source.
DATA Blinking GREEN there is transmit data detected on the network interface
NET ALRM OFF there are no active network alarms on the system.
ON there is an active network alarm on the system.
TEST AMBER the network interface is in test mode (loopback).
V.35 TD Blinking GREEN there is transmit data detected on the V.35 port. This
LED blinks with data traffic.
V.35 RD Blinking GREEN there is received data detected on the V.35 port. This
LED blinks with data traffic.
ETH LI OFF there is no active Ethernet link.
Solid GREEN there is a valid Ethernet link on the 10BaseT interface.
ETH TX/RX Blinking GREEN there is received or transmitted data detected on the
Ethernet interface. This LED blinks with data traffic.