Instruction manual

Section 2 Engineering Guidelines Total Access 850 System Manual
48 © 2004 ADTRAN, Inc. 64203376L1-1B
Specifications
Table 29 provides the detailed specifications for the Total Access 850 UBR1TE Module.
Compliance Codes
Table 30 provides the compliance codes for the Total Access 850 UBR1TE Module.
Table 29. UBR1TE Module Specifications
Loop Interface (ANSI T1.601)
Line
2-wire (tip and ring)
Operating Mode
full duplex
Data Rate
160 kbps total; 144 kbps available to customer
Signal Format
2B1Q
Transmit Power
13 dBm to 14 dBm nominal
DS1 Facility Interface
BR1/10 compatible equipment.
Network Compatibility
Interface
ISDN and other digital service, according to
TR-NWT-000397
Mechanical
Dimensions
3.125” H x 0.62” W, 1.01” D
Weight
< 1 lb
Power
Current Draw
0.023 A maximum (@ -48V)
Environmental
Temperature
Operating: -40 °C to +70 °C
Storage: -40 °C to + 85 °C
Relative Humidity
Up to 95% noncondensing
Heat Dissipation
1.10 W (maximum)
Table 30. UBR1TE Module Compliance Codes
CODE IN OUT
Power Code (PC) CC
Telecommunication Code (TC) –X
Installation Code A–