Instruction manual
Total Access 850 System Manual Section 2 Engineering Guidelines
64203376L1-1B © 2004 ADTRAN, Inc. 49
OCU DP Access Module (P/N 1180005L1)
The OCU DP module is a single port access module used to provide the interface between a DS0 time slot
on the T1 and a 4-wire DDS device at the customer premises. The OCU DP supports up to 18 kft of copper
for remote DSU connectivity. This module is currently only supported by BCU L1 and L2. Table 31 gives
this pinout.
E&M/TO Access Module (P/N 1180402L1)
The E&M/TO module is a single port Ear and Mouth/Transmit Only access module. The primary
application for this module is to provide PBX foreign exchange at the customer premises or tandem central
office applications. The E&M/TO module supports both 2- and 4- wire operation. This module is currently
only supported by BCU L1 and L2. Table 32 gives the E&M/TO module pinout.
The OCU DP Access Module may be used for intra-building networks only. This interface
should not be connected to public networks.
Table 31. OCU DP Pinout
Total Access 850 Slot T/R RX T1/R1 TX
1 26/1 27/2
2 30/5 31/6
3 34/9 35/10
4 38/13 39/14
5 42/17 43/18
6 46/21 47/22
The E&M/TO Access Module may be used for intra-building networks only. This interface
should not be connected to public networks.
Table 32. E&M/TO Pinout
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6
Pin
1 5 9 131721RING
2 6 10 14 18 22 RING 1
3 7 11 15 19 23 SG LEAD
4 8 12 16 20 24 SB LEAD
Pin
26 30 34 38 42 46 TIP
27 31 35 39 43 47 TIP 1
28 32 36 40 44 48 E LEAD
29 33 37 41 45 49 M LEAD