Section 4 User Interface Guide Total Access 850 System Manual
76 © 2004 ADTRAN, Inc. 64203376L1-1B
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > IDLE TIME
This option defines the amount of time in minutes user may stay connected without any activity on the
CRAFT port before the user is automatically logged out of the system. A value of 0 disables this inactivity
timer function enabling users to stay connected until manually logged out. The value range is
0 (def) to 255
(minutes).
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > BAUD RATE
This is the asynchronous rate that the CRAFT port will run. The possible values are 300, 1200, 2400, 4800,
9600, 19200, 38400
, 57600, and 115200. The default value is 9600.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > DATA BITS
This is the asynchronous bit rate that the CRAFT port will run. The possible values are 7 or 8 (def) bits.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PARITY
This is the asynchronous parity that the CRAFT port will run. The possible values are NONE (def), ODD, or
EVEN.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > STOP BITS
This is the number of stop bits used for the CRAFT port. The possible values are 1 (def), 1.5 or 2.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS
Activate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 850
supports up to five simultaneous Telnet sessions.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > ACCESS
Sets ACCESS to ON or OFF. The factory default value for this parameter is ON.
Table 2. Instructions for Changing Passwords
Step Action
1
Select the PASSWORD field—a new PASSWORD field displays.
2 Type the new password in the ENTER field.
3 Type the new password again in the CONFIRM field.
The Total Access 850 ships with default Telnet Access parameters of: guest (user),
password (password). Change this password during the initial configuration to protect
your unit.