Specifications
Users that are inactive or have gone out of wireless range for some period of time are getting dropped 
from active connections of the BSC and have to re-authenticate. An example would be a device that has 
gone into sleep mode or an employee who has taken their laptop with them outside of the wireless 
coverage area for a lunch meeting. 
You can adjust the "Time in seconds before idle connections are timed out" under 
general>misc>connection tracking. The default is 600 seconds (10 minutes). This means if a client is 
inactive or goes away for 10 minutes they will be dropped from the BSC's active connection table and 
have to re-authenticate. You could adjust this to 4 hours for example, 1/2 of a business day. This must be 
set to greater than or equal to your DHCP lease. If you are using the BSC's DHCP server you can find the 
DHCP lease under network>managed>click to edit the appropriate managed network interface>DHCP 
server tab. If you are using DHCP relay make sure the setting is greater than or equal to your DHCP lease 
time in your external DHCP server. If the BSC does not see the DHCP renew at half the lease interval the 
client will be dropped from the connections table.
What are the rack space, environmental, power consumption and thermal output (BTU) 
specifications of the BSCs? 
BSC-600/1200 
Rack Space: 1U Width: 380 mm (15 in) Depth: 290 mm (11.5 in) Height: 44.5 mm (1.75 in) 
Operating Temp: 10 to 35 degrees C (50 to 95 degrees F) 
Humidity: 40 to 80%, non-condensing 
Power Consumption: 110-240V, 220 Watts 
Thermal Output (BTU): 750 BTU/h 
*Optional BSC-600/1200 PoE Power Supply (BSC-POE-000-00-00): 100-240V, 80 Watts, 275 BTU/h 
BSC-2200/3200/5200 
Rack Space: 2U Width: 445 mm (17.5 in) Depth: 450mm (17.7 in) Height: 89 mm (3.5 in) 
Operating Temperature: 10 to 35 degrees C (50 to 95 degrees F) 
Humidity: 40 to 80%, non-condensing 
Power Consumption: 110-240V, 350 Watts 
Thermal Output (BTU): 1200 BTU/hr