Specifications
tagging is performed inside the tunnel and not exposed to the switch. If you are using BlueSecure 
access points you are not required to put the BSAPs or the BSC's managed interface on trunk 
ports. They can be placed on access ports. This may be referred to as untagged ports on some 
switches. The exception to this is the BSAP-1600. BSAP-1600s do not support EtherIP 
tunneling. 
3rd Party Access Points 
If you are using 3rd party access points and you want to deploy multiple ssid assigned to 
multiple managed side vlans both the 3rd party access points and the BSC's managed interface 
must be placed on trunk ports. This may be referred to as tagging vlans on some switches. Here 
is an example vlan setup with the BSC, 3rd Party AP and Cisco switches. 
-BSC's protected physical interface on vlan 5. This could be the existing wired network or a dmz. 
-BSC's managed physical interface on vlan 10. Vlan 10 is used for 3rd party AP management in 
this example.   
-Employee ssid assigned to managed vlan 15 
-Guest ssid assigned to managed vlan 20 
BSC's Protected Interface Switchport Configuration 
Switchport mode access vlan 5 
BSC's Managed Interface Switchport Configuration 
Switchport mode trunk 
Switchport trunk encapsulation dot1q 
Switchport trunk allowed vlan 10,15,20 
Switchport trunk native vlan 10 
3rd Party APs switchport Configuration 
Switchport mode trunk 
Switchport trunk encapsulation dot1q 
Switchport trunk allowed vlan 10,15,20 
Switchport trunk native vlan 10 
***The physical interfaces of the BSC cannot send or receive dot1q tags, only the vlan 
interfaces can. Notice above the protected physical interface is on an access port (untagged) 
and the managed physical interface is on the native vlan of the trunk (untagged). 
Here is the same example vlan setup with HP switches.  
vlan 5 
untagged e10 
vlan 10 
untagged e11,e12 
vlan 15 
tagged e11,e12 
vlan 20 