Specifications
Chapter 8. Troubleshooting
61203153L3-20 Express 3000 SP User Manual 8-3
Express 3000 SP not detected.
The Express 3000 SP may not be detected for several reasons. 
1. Verify the following:
a. The Express 3000 SP is powered on.
b. No other applications are running that could be using the 
COM port to which the Express 3000 SP is attached. 
A Windows application does not have to be active to tie up a 
COM port. Be sure to check the Windows 95/98 Taskbar for 
any suspended applications (such as HyperTerminal) that 
may be using the COM port. If any applications are mini-
mized, they must be closed 
before
 starting the ADTRAN 
Express Configuration program. 
2. If you are operating at 230.4 kbps, move 
DIP switch 1
 to 
Off
(up)
. 
3. Confirm that the computer has a 16650 UART.
Difficulty with 230.4 kbps operation.
If the Express 3000 SP does not work when the DTE rate is set (inside 
Windows) to 230.4 kbps, verify the following:
1.
DIP switch 1
 on the back of the Express 3000 SP is set to 
Off (up)
.
2. A high-speed serial card with a 16650 UART is being used, and 
the software drivers to support the extended baud rate tables are 
installed.










