Technical information
Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000
38 www.polycom.com
Serial Interface Control Signals
If you need to customize your V.35/RS-449/RS-530 interface, use 
the signal information in Table 2-21 below in addition to the 
information provided by your network equipment vendor. 
Table 2-21. Serial Interface Control Signals
Signal 
(Pin) In/Out Description Configuration Option
ST 
(TC/TT)
OUT Send Timing 
(clock)
Normal: falling edge sends data
Inverted: rising edge sends data
RT (RC) IN Receive 
Timing (clock)
Normal: rising edge receives 
data
Inverted: falling edge receives 
data
RTS 
(RTS)
OUT Request To 
Send
Normal: high is logic 1
Inverted: low is logic 1
DCD 
(DCD)
IN Data Carrier 
Detect
Normal: high is logic 1
Inverted: low is logic 1
Filter: allow DCD to drop for 60 
seconds before changing call 
state
CTS 
(CTS)
IN Clear To Send Normal: high is logic 1
Inverted: low is logic 1
DTR 
(DTR)
OUT Data Terminal 
Ready
Normal: high is logic 1
Inverted: low is logic 1
On: signal remains high
a
a. If set to ON, inverted is not an option.
DSR 
(DSR)
IN Data Set 
Ready
Normal: high is logic 1
Inverted: low is logic 1
Answer: Use DSR as a Ring-In 
indication
b
b. DSR is not used as a ring-in indication if it is set to ANSWER in 
the V.35 Advanced Setup screen.