Product specifications

Section 61181113L2-5A
Issue 1, November 2003
CLEI Code: T1L7HGLA _ _
61181113L2-5A 1
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
CONTENTS
1. General...................................................................................... 1
2. Description................................................................................ 1
3. Connections .............................................................................. 3
4. Installation ................................................................................ 4
5. HDSL2 System Testing ............................................................ 6
6. SCU Control Port Operation-HDSL2 ....................................... 7
7. Provisioning .............................................................................. 8
8. HDSL2 Deployment Guidelines ............................................. 30
9. Troubleshooting Procedures ................................................... 31
10. Maintenance............................................................................ 31
11. Product Specifications ............................................................ 31
12. Warranty and Customer Service ............................................. 31
Appendix A. HDSL2 Loopbacks ........................................... A-1
Appendix B. Front Panel DSX and MUX Mode Test Access B-1
TABLES
Table 1. ADTRAN HDSL2 Unit Compatibility....................... 1
Table 2. Compliance Codes ...................................................... 3
Table 3. Front Panel LEDs ....................................................... 5
Table 4. Provisioning Options .................................................. 8
Table 5. Auto In Service Status Indications ........................... 15
Table 6. HDSL2 Loss Values ................................................. 30
Table 7. Troubleshooting Guide ............................................. 31
Table 8. HDSL2 Total Access 3000 H2TU-C Specifications 32
Table A-1. HDSL2 Loopback Control Codes.......................... A-2
Table A-2. In-Band Addressable Loopback Codes ................. A-3
1. GENERAL
The ADTRAN Total Access
®
3000 2-Wire HDSL
(HDSL2) Transceiver Unit for the Central Office
(H2TU-C) (P/N 1181113L2) is used to deploy an
HDSL2 T1 circuit using 2-wire metallic facilities. The
unit occupies one slot in a Total Access 3000 or Total
Access 3010 Shelf. Figure 1 is an illustration of the
ADTRAN Total Access 3000 H2TU-C.
Revision History
This is the initial release of this document. Future
revisions to this document will be explained in this
subsection.
2. DESCRIPTION
The DSX-1 input signal can be supplied from the
network or a Total Access 3000 Multiplexer (DS3,
STS-1, or OC-3).
Figure 1. Total Access 3000 H2TU-C
DSX-1 signals are provided to and received from the
network, while HDSL2 signals are provided to the local
loop. The ADTRAN Total Access 3000 H2TU-C works
in conjunction with the ADTRAN H2TU-R to provide
a DS1 service up to 12,000 feet on the local loop.
Compatible ADTRAN units for this H2TU-C are shown
in Table 1.
x = any generic number
The H2TU-C can be deployed in circuits consisting of
one H2TU-C and one H2TU-R.
Table 1. ADTRAN HDSL2 Unit Compatibility
Part Number Description
122x024L2 T200 H2TU-R, Local Power
122x026L2 T200 H2TU-R, Span Power
1181113L2
H TUCH TUC
DSL
DSX
ALM
B8ZS/ALM
(YEL) (GRN)
ESF/ SF
(YEL) (GRN)
LBK
TX
RX
E
Q
M
O
N
TX
RX
SCAN
Total Access 3000 H2TU-C,
HDSL2 Transceiver Unit for the Central Office
Installation and Maintenance Practice

Summary of content (40 pages)