Troubleshooting guide
MX2820 System Manual
5-14 61186003L1-1D
M13 MUX MENU TREE
Figure 5-3 shows the menu tree for the MX2820 M13 Multiplexer (MUX) module.
Figure 5-3. MX2820 M13 MUX Menu Tree
1. Configuration
2. Provisioning
3. Status
4. Test
5. Performance Monitoring
4. Protection
Note: An asterisk (*) indicates default setting
5. Save Provisioning
1. 0-133 ft*
T1:
E1:
3. 266-399 ft
2. 133-266 ft
5. 533-655 ft
1. 0-6dB Loss
4. 399-533 ft
1. 2 seconds*
29. Set Multiple
30. Auto Enable Delay
3. 2 hours
2. 1 hour
5. 1 day
4. 12 hours
6. 2 days
7. 7 days
1. Disabled
3. 5 Minutes*
2. 1 Minute
5. 15 Minutes
4. 10 Minutes
6. 30 Minutes
7. 45 Minutes
8. 60 Minutes
1. Near End Daily
3. Far End Daily
2. Near End Quarter Hourly
5. Near End Daily Thresholds
4. Far End Quarter Hourly
6. Near End Quarter Hourly Thresholds
7. Near End Daily Thresholds
8. Near End Quarter Hourly Thresholds
9. Clear DS3 Statistics
1. Data Mode*
3. Digital Loopback
2. Line Loopback
5. Remote ALL T1/E1
4. Remote Loopback
1. QRSS*
3. ALL ZEROES
2. ALL ONES
5. 1 in 8 (1:7)
4. 2 in 8 (2:6)
6. 2 ^15-1 INV
1. Data Mode*
2. Network Loopback
1. Data Mode*
T1:
3. Analog Network
2. Tributary
5. CODEC Line/Net
4. Digital Line/Net
6. Remote Loopback
7. LS CSU Loopback
8. LS CSU LB w/BERT
9. LS NIU Loopback
10. LS NIU LB w/BERT
11. LS Line BERT
1. Data Mode*
E1:
T1/E1 Loopbacks (T1/E1 #1-28)
29. DS3 Loopbacks
3. Analog Network
2. Tributary
5. CODEC Line/Net
4. Digital Line/Net
6. Remote Loopback
7. Line BERT
CLEI Code
Serial Number
Part Number
Code Checksum
Code Version
Boot Version
Boot Checksum
Self Test
1. Disabled*
3. 1E-4
2. 1E-3
5. 1E-6
4. 1E-5
1. Disabled*
3. 1E-4
2. 1E-3
5. 1E-6
4. 1E-5
1. Near End Daily
3. Near End Daily Thresholds
2. Near End Quarter Hourly
4. Near End Quarter Hourly Thresholds
5. Clear T1/E1 Statistics
1. Disabled
3. FEAC
2. FEAC/C-BIT*
4. C-BIT
1. DS3 Framing
3. DS3 Remote Loopbacks
2. DS3 Timing
7-13. DS2 Mode (DS2 #1-7)
4. DS3 XCV Threshold
1. T1/E1 State
3. T1/E1 Line Length
2. T1/E1 Line Coding
5. T1/E1 Circuit Protection
4. T1/E1 Loopback Detection
6. T1/E1 Line Identification
7. T1/E1 XCV Threshold
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
7. Card Reset
1. Network Interface
2. T1/E1 Interfaces
3. Service States
6. Restore Factory Defaults
8. Auto Save
9 . Loopback Timeout
10 . Card Pair ID
1. AMI
2. B8ZS/HBD3*
1. Disabled
2. Enabled
3. Auto Enable*
T1/E1 #1-28
29. DS3
30. Set Multiple
1. Card A
2. Card B
3. Facility Service States
2. Enabled*
1. Disabled
30. Protection Threshold (1-28): 1*
2. Enabled*
1. Disabled
1. Disabled*
2. CSU (T1 Only)
3. NIU (T1 Only)
1. Perform Manual Switch
2. Minimum Switching Period (sec.) (10*)
3. Maximum Switch Threshold (3*)
1. DS3 Statistics
2. T1/E1 Statistics
3. Clear ALL Statistics
1. M12 (4xT1)*
2. G.747 (3xE1)
1. C-BIT
2. M13*
1. IS*
2. OOS
1. Loop
2. Local*
30-36. DS2 #1-7 Loopbacks
37. Reset ALL Tests
38. Pattern
14. DS3 Equipment Identification
(T1/E1 #1-28)
Shelf: 1 Slot: 1A ADTRAN MX2820 System 04/15/04 16:33
Unacknowledged Alarms: CRITICAL MAJOR TID: SysName not set
Status
DS3 State DS2 State
State = ALARM <1-7> = NA NA NA NA NA NA NA
Alarm = LOS
Rx Framing = M13 T1/E1 State
Remote = Unknown <1-4> = AUTO AUTO AUTO AUTO
<5-8> = AUTO AUTO AUTO AUTO
Multiplexer State <9-12> = AUTO AUTO AUTO AUTO
Alarm = None <13-16> = AUTO AUTO AUTO AUTO
Protection = Circuit <17-20> = AUTO AUTO AUTO AUTO
Card Comm. = OK <21-24> = AUTO AUTO AUTO AUTO
<25-28> = AUTO AUTO AUTO AUTO
Slot 1A
Status = Active
Slot 1B
Status = Standby
’?’ - System Help Screen
12. HS CSU Loopback
13. HS CSU LB w/BERT
14. HS NIU Loopback
15. HS NIU LB w/BERT
16. HS Line BERT
5. IP Forwarding Protocol
6. IP Forwarding MTU
1. ADTRAN*
2. PPP
1. 260 (PREFERRED)*
2. 1500
4. Clear Number of Switches