Troubleshooting guide

Section 5, User Interface Guide - UIG-520, M13 MUX PM Statistics
61186003L1-1D 5-49
DS3 Far-End Quarter Hourly Thresholds and Alarms
Select FAR END QUARTER HOURLY THRESHOLDS from the DS3 Statistics menu screen.
Figure 5-21 shows an example of the Far-End Quarter Hourly Thresholds menu screen.
Figure 5-21. DS3 Far-End Quarter Hourly Thresholds
The menu screen for the selected PM parameter appears. The user is then able to set the
threshold to the desired level and enable/disable an alarm to be issued once that threshold is
exceeded.
NOTE
Options at the bottom of the menu are used to restore all DS3 and
DS1 defaults.
Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/15/04 02:44
Unacknowledged Alarms: None TID: HTVLALEXD16
DS3 Statistics - Far End Quarter Hourly Thresholds
Threshold Alarm
1 - CVCP-P : 382 Disabled
2 - ESCP-P : 25 Disabled
3 - SESCP-P : 4 Disabled
4 - UASCP-P : 10 Disabled
5 - Restore ALL DS3 and DS1 Threshold Defaults
6 - Enable ALL DS3 and DS1 Threshold Alarms
7 - Disable ALL DS3 and DS1 Threshold Alarms
Selection: '?' - System Help Screen