Troubleshooting guide
Section 5, User Interface Guide - UIG-520, M13 MUX PM Statistics
61186003L1-1D 5-59
Figure 5-31. T1/E1 Quarter Hourly Thresholds Screen - For P/N 1186002L3 Only
Select the desired PM parameter, and press ENTER. The menu for the selected PM parameter
appears. The user is then able to set the threshold to the desired level and enable/disable an
alarm to be issued once that threshold is exceeded.
NOTE
Options at the bottom of the menu are used to restore all DS3 and
DS1 defaults.
Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/15/04 02:44
Unacknowledged Alarms: None TID: HTVLALEXD16
T1/E1 Statistics - Near End Quarter Hourly Thresholds
Threshold Alarm
1 - CV-L : 387 Disabled
2 - ES-L : 25 Disabled
3 - SES-L : 4 Disabled
4 - LOSS-L : 10 Disabled
5 - CV-P : 387 Disabled
6 - ES-P : 25 Disabled
7 - SES-P : 4 Disabled
8 - UAS-P : 2 Disabled
9 - AISS-P : 10 Disabled
10 - Restore ALL DS3 and DS1 Threshold Defaults
11 - Enable ALL DS3 and DS1 Threshold Alarms
12 - Disable ALL DS3 and DS1 Threshold Alarms
Selection: '?' - System Help Screen