Troubleshooting guide
Section 5, User Interface Guide - UIG-525, STS-1 MUX PM Statistics
61186003L1-1D 5-71
STS-1 Near-End Daily Thresholds and Alarms
1. Select NEAR END DAILY THRESHOLDS, from the STS-1 Statistics screen.
Figure 5-38 shows an example of the Near-End Daily Thresholds menu screen.
Figure 5-38. STS-1 Near-End Daily Thresholds
2. Input the number of the desired PM parameter, and press ENTER.
The menu screen for the selected PM parameter appears. The user is then able to set the
threshold to the desired level and enable/disable an alarm to be issued once that threshold is
exceeded.
Options at the bottom of the menu are used to restore all STS-1 and VT/Port threshold
defaults.
Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/16/04 09:02
Unacknowledged Alarms: None TID: HTVLALEXD16
STS-1 Statistics - Near End Daily Thresholds
Threshold Alarm
1 - CV-L : 382 Disabled
2 - ES-L : 25 Disabled
3 - SES-L : 4 Disabled
4 - UAS-L : 10 Disabled
5 - CV-S : 382 Disabled
6 - ES-S : 25 Disabled
7 - SES-S : 10 Disabled
8 - SEFS-S : 4 Disabled
9 - CV-P : 382 Disabled
10 - ES-P : 25 Disabled
11 - SES-P : 4 Disabled
12 - UAS-P : 10 Disabled
13 - PPJC-P : 5 Disabled
14 - NPJC-P : 5 Disabled
15 - Restore ALL STS-1, VT, and DS1 Threshold Defaults
16 - Enable ALL STS-1, VT, and DS1 Threshold Alarms
17 - Disable ALL STS-1, VT, and DS1 Threshold Alarms
Selection: '?' - System Help Screen