Troubleshooting guide
Section 5, User Interface Guide - UIG-525, STS-1 MUX PM Statistics
61186003L1-1D 5-73
STS-1 Far-End Daily Thresholds and Alarms
Select FAR END DAILY THRESHOLDS from the STS-1 Statistics menu screen.
Figure 5-40 shows an example of the Far-End Daily Thresholds menu screen.
Figure 5-40. STS-1 Far-End Daily Thresholds
Input the number of the desired PM parameter, and press ENTER.
The menu screen for the selected PM parameter appears. The user is then able to set the
threshold to the desired level and enable/disable an alarm to be issued once that threshold is
exceeded.
NOTE
Options at the bottom of the menu are used to restore all STS-1
and VT/Port threshold defaults.
Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/16/04 09:10
Unacknowledged Alarms: None TID: HTVLALEXD16
STS-1 Statistics - Far End Daily Thresholds
Threshold Alarm
1 - CV-L : 382 Disabled
2 - ES-L : 25 Disabled
3 - SES-L : 4 Disabled
4 - UAS-L : 10 Disabled
5 - CV-P : 382 Disabled
6 - ES-P : 25 Disabled
7 - SES-P : 4 Disabled
8 - UAS-P : 10 Disabled
9 - Restore ALL STS-1, VT, and DS1 Threshold Defaults
10 - Enable ALL STS-1, VT, and DS1 Threshold Alarms
11 - Disable ALL STS-1, VT, and DS1 Threshold Alarms
Selection: '?' - System Help Screen