Troubleshooting guide

MX2820 System Manual
5-74 61186003L1-1D
STS-1 Far-End Quarter Hourly Thresholds and Alarms
Select FAR END QUARTER HOURLY THRESHOLDS from the STS-1 Statistics menu screen.
Figure 5-41 shows an example of the Far-End Quarter Hourly Thresholds menu screen.
Figure 5-41. STS-1 Far-End Quarter Hourly Thresholds
Input the number of the desired PM parameter, and press ENTER.
The menu screen for the selected PM parameter appears. The user is then able to set the
threshold to the desired level and enable/disable an alarm to be issued once that threshold is
exceeded.
NOTE
Options at the bottom of the menu are used to restore all STS-1
and VT/Port threshold defaults.
Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/16/04 09:12
Unacknowledged Alarms: None TID: HTVLALEXD16
STS-1 Statistics - Far End Quarter Hourly Thresholds
Threshold Alarm
1 - CV-L : 382 Disabled
2 - ES-L : 25 Disabled
3 - SES-L : 4 Disabled
4 - UAS-L : 10 Disabled
5 - CV-P : 382 Disabled
6 - ES-P : 25 Disabled
7 - SES-P : 4 Disabled
8 - UAS-P : 10 Disabled
9 - Restore ALL STS-1, VT, and DS1 Threshold Defaults
10 - Enable ALL STS-1, VT, and DS1 Threshold Alarms
11 - Disable ALL STS-1, VT, and DS1 Threshold Alarms
Selection: '?' - System Help Screen