Troubleshooting guide

61186003L1-1D 7-81
DLP-716
Logging on to the System
INTRODUCTION
This procedure provides step-by-step instructions to logon to the MX2820 system. Once
connected to the MX2820 System Controller Unit (SCU) via either a VT100 terminal or PC
configured as a VT100 terminal, it is necessary to logon to the system to gain access to the
management and provisioning functions.
A logon can be performed through the security of the MX2820 SCU or can require further
authentication by a RADIUS server (Remote Authentication Dial In User Service) in accor-
dance with procedures provided in IETF standard RFC2865.
Refer to “UIG-560, RADIUS” for additional information.
PREREQUISITE PROCEDURES
The following procedures must be completed before logging onto the system. If necessary, refer
to the appropriate documentation before proceeding.
“NTP-006, SCU Provisioning (System Security)”
“DLP-715, Connect Terminal or PC to Craft Port”
ACCOUNT NAME AND PASSWORD
The default account name and password are to be entered in all capital letters. The MX2820
system has four levels of access granted to a user. The lowest level of access is READONLY,
and allows the user to see, but not change the current system configuration. The next level,
READWRITE, allows the user to both see and change system configuration parameters. The
third level of access is the TEST level. This access level allows system testing. The fourth,
ADMIN, is reserved for system or network administrators. Table 7-4 provides the account
names and passwords for the MX2820 system