Troubleshooting guide

MX2820 System Manual
7-114 61186003L1-1D
6. From the Access Modules Provisioning menu, select NETWORK INTERFACE and press ENTER.
Figure 7-28 shows the DS3/DS2 Network Provisioning Menu.
Figure 7-28. DS3/DS2 Network Provisioning Menu
7. From the Network Provisioning menu, select DS3 FRAMING and press ENTER.
8. Input a value to set the DS3 framing format to match the format of the receive signal at
the network interface, and press
ENTER.
Select 1 for C-BIT framing.
Select 2 for M13 framing.
9. From the Network Provisioning menu, select DS3 TIMING and press ENTER.
10. Input a value to set the desired DS3 timing and press
ENTER.
Select 1 for Loop timing if the M13 MUX connects to a network that provides timing.
Select 2 for Local timing if the M13 MUX provides the master timing source for the
circuit.
11. From the Network Provisioning menu, select option 3, DS3 REMOTE LOOPBACKS, and press
ENTER.
12. Input a value from 1 to 4, and press
ENTER.
Select 1, DISABLE, to ignore all out-of-band requests (FEAC and DS2 C-BIT). The M13
MUX still responds to individual T1 in-band CSU/NIU loopbacks if configured with the
T1/E1 Loopback Detection menu.
Select 2, FEAC/C-BIT, to allow the M13 MUX to respond to remote loopback requests
received over either the DS3 Far End Alarm and Control (FEAC) channel and/or DS2-
level C-bits. This mode is valid for both C-BIT and M13 framing formats.
Shelf: 1 Slot: 1A ADTRAN MX2820 System 07/26/04 16:57
Unacknowledged Alarms: MAJOR TID: HTVLALEXD16
Network Provisioning
1 - DS3 Framing : C-BIT
2 - DS3 Timing : Local
3 - DS3 Remote Loopbacks : FEAC/C-BIT
4 - DS3 XCV Threshold : Disabled
5 - IP Forwarding Protocol: ADTRAN
6 - IP Forwarding MTU : 260 (PREFERRED)
7 - DS2 #1 Mode : M12 <4xT1>
8 - DS2 #2 Mode : M12 <4xT1>
9 - DS2 #3 Mode : M12 <4xT1>
10 - DS2 #4 Mode : M12 <4xT1>
11 - DS2 #5 Mode : M12 <4xT1>
12 - DS2 #6 Mode : M12 <4xT1>
13 - DS2 #7 Mode : M12 <4xT1>
14 - DS3 Equipment Identification
Selection: '?' - System Help Screen