Troubleshooting guide
Section 7, User Interface Guide - DLP-732, Provision SNMP Management Options
61186003L1-1D 7-125
5. From the Provisioning menu, select SNMP.
Figure 7-37 shows the SNMP menu.
Figure 7-37. SNMP Menu
NOTE
For step 6, the MX2820 system sends traps to these SNMP man-
ager IP addresses.
6. From the SNMP menu, select TRAP HOST 1 IP.
7. From the Trap Host 1 IP menu, select 1, and press
ENTER.
8. Input Trap Host 1 IP address, and press
ENTER.
9. From the Trap Host 1 IP menu, select 2, and press
ENTER.
10. Input one of the following values, and press
ENTER to set the Trap Host 1 Status:
• 1 - Valid
• 2 - Create Request
• 3 - Under Creation
• 4 - Invalid
11. Repeat steps 6 - 10 for Trap Host 2, 3, and 4, by selecting options 2, 3, and 4 respectively
in step 6. After inputting this information, proceed to step 12.
12. From the SNMP menu, select
IFINDEX METHOD.
Shelf: 1 ADTRAN MX2820 System 04/26/04 14:04
Unacknowledged Alarms: None TID: HTVLALEXD16
SNMP
1 - Trap Host 1 IP : 0.0.0.0
2 - Trap Host 2 IP : 0.0.0.0
3 - Trap Host 3 IP : 0.0.0.0
4 - Trap Host 4 IP : 0.0.0.0
5 - ifIndex Method : Sequential (RFC2863)
6 - SCU Traps : ENABLE
7 - System Name : HTVLALEXD16
8 - System Location : SysLocation not set
9 - System Contact : www.adtran.com
10 - Read Community : public
11 - Write Community : private
Selection : '?' - System Help Screen