Troubleshooting guide

MX2820 System Manual
7-164 61186003L1-1D
NOTE
In the case of 1:1 protection, provisioning the Active STS-1 MUX
module automatically provisions the Standby STS-1 MUX module.
PROCEDURE
1. If not already connected, connect the VT100 terminal or PC to the craft port. For details,
refer to
DLP-715.
2. Logon to the MX2820 system. For details, refer to DLP-716.
3. From the MX2820 Main Menu, select
ACCESS MODULE and press ENTER.
4. From the Access Module Menus screen, select the slot number for the STS-1 MUX module
that is to be provisioned, and press
ENTER.
Figure 7-60 shows the STS-1 Main Menu screen.
Figure 7-60. STS-1 Main Menu
Shelf: 1 ADTRAN MX2820 System 05/04/04 09:29
Unacknowledged Alarms: None TID: HTVLALEXD16
Main Menu
1 - Configuration
2 - Provisioning
3 - Status
4 - Test
5 - Performance Monitoring
Selection: '?' - System Help Screen