Troubleshooting guide
MX2820 System Manual
8-22 61186003L1-1D
Clock Module Alarms
Table 8-18 describes the alarms for the MX2820 Clock Module.
Table 8-18. Clock Module Alarms
General Alarm Description Severity Level
HO Holdover: The clock circuitry is locked and no longer
tracking the external clock reference
Major
CONTCOM Card Communication: Communication between the two
installed Clock Modules in a protected arrangement has
failed
Minor
EQPT Equipment Failure: A Non-Service Affecting equipment
problem has occurred
Minor
IMPROPRMVL Card Removal: An improper removal of a Clock Module
has occurred
Minor/Critical
Minor if protection is
available; Critical if
not
PRIFAIL Primary Clock Fail: The Clock Module has detected a fail-
ure condition on the Primary clock input
Minor
SECFAIL Secondary Clock Fail: The Clock Module has detected a
failure condition on the Secondary clock input
Minor
WKSWPR Switch to Protect: The system has switched to the protect
module (card B) in the protected pair
Alert
EWS Excessive Switches: The number of switches to protec-
tion has exceeded the threshold
Alert