NT1 ACE3 USER MANUAL 1200236L1: 336012VUR01: 61200236L1-1A June 1998 NT1 ACE3 Power Supply 12 VDC/800 mA
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of the FCC rules. On the bottom of the equipment housing is a label that shows the FCC registration number and Ringer Equivalence Number (REN) for this equipment. If requested, provide this information to the telephone company. 2. If this equipment causes harm to the telephone network, the telephone company may temporarily discontinue service.
5. This unit contains no user serviceable parts. 6. An FCC compliant telephone cord with a modular plug is provided with this equipment. In addition, an FCC compliant cable appropriate for the dial backup option ordered is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using an FCC compatible modular jack, which is Part 68 compliant. 7.
CANADIAN EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of the Department of Communications.
CANADIAN EQUIPMENT LIMITATIONS Notice: The Canadian Industry and Science Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, ensure that it is permissible to be connected to the facilities of the local telecommunications company.
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or an electrician, as appropriate. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading.
Table of Contents Unit Overview ............................................................... LED Indicators............................................................... Inspection ....................................................................... Maintenance................................................................... Remote Testing .............................................................. Repair and Return ......................................................... Connections..........
Table of Contents FIGURES Figure 1-1. ADTRAN NT1 ACE3 ........................................1 Figure 1-2. 1Interface Connectors .......................................1 Figure 1-3. Network Connector (RJ-45) ............................. 5 Figure 1-4 . Local Bus Connector (RJ-45) ............................6 Figure 1-5. Power Supply Connection ................................7 Figure 1-6. Typical Configuration........................................9 TABLES Table 1-A. Status Indicators..................
NT1 ACE3 User Manual Unit Overview The ADTRAN NT1 ACE3 provides up to three basic rate interfaces between customer ISDN terminal equipment (S/T) and the ISDN network (U). Figure 1-1 is an illustration of the NT1 ACE3. 3 2 1 READY ERROR READY ERROR READY ERROR NT1 ACE3 Figure 1-1 ADTRAN NT1 ACE3 12VDC 3 POWER S/T 2 U S/T 1 U S/T U Figure 1-2 Interface Connectors The three RJ-45 connectors labeled U connect to the ISDN network.
NT1 ACE3 User Manual The U-interface complies with ANSI T1.601 and ITUTI.430 recommendation Standard. The S/T-interface complies with ANSI T1.605 and ETSI ETS 300012 Standard. The ADTRAN NT1 ACE3 is a stand-alone unit. An external power source is provided for the NT1 ACE3. External power is supplied by the ADTRAN Power Supply, part number 336012VUR01. LED Indicators Table 1-A describes the status of the LEDs located on the front panel of the NT1 ACE3.
NT1 ACE3 User Manual network problem. A slower 1 Hz rate (1 flash per second) indicates an S/T interface problem. If an ERROR indicator is not illuminated and the READY indicator is flashing, then a network test is in progress. Network command tests cause a faster 8 Hz flash rate. Inspection After unpacking the unit, immediately inspect it for possible shipping damage. If damage is discovered, file a claim immediately with the carrier; then contact ADTRAN Customer Service.
NT1 ACE3 User Manual Maintenance The ADTRAN NT1 ACE3 requires no routine maintenance to operate. In case of equipment malfunction, refer to the sections Remote Testing on page 4 and Repair and Return on page 4 or remove the unit and replace it with another unit optioned in an identical manner. Remote Testing Network test features include a loopback test initiated at the central office. This test confirms network integrity to the NT1 ACE3. Repair and Return Repairs should not be performed in the field.
NT1 ACE3 User Manual Connections The NT1 ACE3 is optioned for standard 100Ω termination. Tables 1-B and 1-C give the connector pin assignments, and Figures 1-3 and 1-4 show the connectors.
NT1 ACE3 User Manual Table 1-C Local Bus Connector Pin Assignments Pin 1 2 3 4 5 6 7 8 Description No connection No connection S/T interface Receive Power Source 1 (Negative) S/T interface Transmit Power Source 1 (Positive) S/T interface Transmit Power Source 1 (Positive) S/T interface Receive Power Source 1 (Negative) No connection No connection PIN 1 PIN 8 Figure 1-4 Local Bus Connector (RJ-45) 6 NT1 ACE3 User Manual 61200236L1-1
NT1 ACE3 User Manual Powering with the NT1 ACE3 Power Supply The ADTRAN NT1 ACE3 Power Supply, part number 336012VUR01, provides power to the NT1 ACE3. To connect the NT1 ACE3 to the external power supply, perform the following steps as illustrated in Figure 1-5. 1. Connect the Power Supply to the NT1 ACE3 at the POWER jack located on the NT1 ACE3 rear panel. 2. Plug the Power Supply into the nearest wall outlet supplying 120 VAC, 60 HZ. 3. On the NT1 ACE3, verify that the ERROR indicators are illuminated.
NT1 ACE3 User Manual Connecting the Terminal Equipment After successfully powering up the NT1 ACE3, the ERROR indicators should be on and the READY indicators should be flashing. Make sure that terminal equipment (TE) is properly terminated. Plug each TE into one of the S/T connectors at the rear of the unit. The ERROR indicators should extinguish a few seconds after power is applied to the TE. If the ERROR indicators fail to go out, see the section Troubleshooting on page 10.
NT1 ACE3 User Manual Typical Configuration This configuration allows you to connect up to three TEs at ranges up to 3000 feet from the NT1 ACE3, as shown in Figure 1-6. A termination resistor should be centrally located to the TEs. The NT1 ACE3 TERMINATION is set to 100 Ω. The TEs should be set to 100 Ω.
NT1 ACE3 User Manual Troubleshooting If your NT1 ACE3 does not operate properly, please check the list of symptoms and solutions below. For further assistance, please contact ADTRAN Technical Support at 888 4ADTRAN. ERROR and READY indicators not illuminated. • Check the power source to the NT1 ACE3 for sufficient power. • The NT1 ACE3 power supply may be defective: Call ADTRAN Technical Support. • The NT1 ACE3 may be defective: Call ADTRAN Technical Support.
NT1 ACE3 User Manual ERROR indicators illuminated, READY indicators flash at a slower 1Hz rate. Local bus failure: • TE not connected: Connect TE. • TE not receiving power from NT1: Consult TE documentation. • TE not terminated properly: Correct termination. • TE ISDN parameters not configured properly: Reconfigure TE (SPIDs, LDNs, switch type, etc.). READY indicators do not illuminate. • Problem with ISDN network: Contact telephone company. • ISDN line not plugged into U jack: Plug ISDN line into U jack.
NT1 ACE3 User Manual Specifications Network Interface (U) Line............................. 2-Wire (Tip and Ring) Operating Mode .......... Full-Duplex Data Rate .................... 160 kbps total, 144 kbps to customer Signal Format............... 2B1Q Output Amplitude ......... 2.5 volts, zero-to-peak Tx Source Impedance .... As per ANSI T1.601 Rx Source Impedance.... As per ANSI T1.601 Receiver Sensitivity........ As per ANSI T1.601 Customer Interface (S/T) Line.............................
NT1 ACE3 User Manual Network Compatibility U Interface............. ISDN U S/T Interface.......... ISDN S/T Mechanical Size...................... 9.0" wide, 6.375" deep, 1.625" high Weight ................. 1.5 lbs Mounting............... Wall or desktop Power 12 VDC ................ 3.3 W dissipation Environmental Temperature .......... 0 to 40 °C (32 to 104 °F) operating -20 to 70 °C (-4 to 158 °F) storage Relative Humidity.... Up to 95%, non-condensing Power Supply Specifications Size..........
NT1 ACE3 User Manual 14 NT1 ACE3 User Manual 61200236L1-1
Technical Support and Warranty Information Presales Inquiries and Applications Support Please contact your local distributor, ADTRAN Applications Engineering, or ADTRAN Sales: Applications Engineering 800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN Technical Support and have the unit serial number available.