Specifications

61181409L10-5B 1
Total Access
®
3000/3010
Quad T1/E1 IMA Module
Installation and Maintenance
Section 61181409L10-5B
Issue 1, January 2003
CLEI Code: SIAPJX0B _ _
CONTENTS
1. GENERAL .................................................................. 1
2. INSTALLATION ....................................................... 2
3. OPERATION ..............................................................2
4. MENU STRUCTURE ................................................4
5. SPECIFICATIONS ..................................................11
6. MAINTENANCE ..................................................... 12
7. WARRANTY AND CUSTOMER SERVICE .........12
FIGURES
Figure 1. Total Access Quad T1/E1 IMA Module.........1
Figure 2. Quad T1/E1 IMA Access Module
Menu Tree .......................................................4
Figure 3. IMA Group Provisioning Menu...................... 6
Figure 4. Quad T1/E1 IMA Access Module
Status Screen (Group 1) .................................. 9
TABLES
Table 1. Compliance Codes .......................................... 2
Table 2. Front Panel LED Indicators ............................3
Table 3. Provisioning Options for the Quad T1/E1
IMA Module.................................................... 5
Table 4. State and Status Definitions ..........................10
Table 5. Loopback Tests for the Quad T1/E1
IMA Module..................................................11
Table 6. Quad T1/E1 IMA Module Specifications .....11
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
1. GENERAL
This practice is an installation and maintenance guide
for the Total Access 3000/3010 Quad T1/E1 Inverse
Multiplexing for ATM (IMA) Access Module, P/N
1181409L10, illustrated in Figure 1. The Quad T1/
E1 IMA Module is used exclusively for ATM
applications.
Revision History
This is the second release of this document.
Information has been added to include E1 menus and
functions.
Features
The Quad T1/E1 IMA access module incorporates the
following features:
Complies with ATM Forum IMA Spec Version
1.1, AF-PHY-0086.001 for up to four DS1/E1
links.
Performs Inverse Multiplexing over ATM (IMA)
for up to four DS1/E1 links.
Supports one to four IMA Groups.
Supports from one to four DS1/E1 interfaces in a
single IMA group.
Supports maximum of 100 ms differential link
delay.
Functions as network or subscriber side ATM
IMA connection in conjunction with an ATM
Cell Switch Module.
Provides the upstream connection to a network
ATM switch.
Provides downstream link to other subtended
DSLAM systems.
Combines NxDS1 links into a single high-speed
link to the ATM Cell Switch Module (CSM).
Continues operating (at a reduced rate) when a
DS1/E1 link failure occurs, and automatically
restores when failure clears.
Delivers a variety of high-speed services.
Figure 1. Total Access Quad T1/E1 IMA
Module
IMA
1181409L10

Summary of content (12 pages)